Measurements and simulation of received signals in rooms and corridors at 900 MHz and in the 20-60 GHz band
Notice bibliographique
Résumé
The authors discuss CW measurements and simulations of received signals in a room, in corridors, and around corners at 900 MHz and at three frequencies in the 20-60-GHz band, namely, 21.6, 37.2 and 59.6 GHz. Reported measurements include signal transmission with directional antennas in corridors and rooms and around corners with the transmitting station stationary and the receiving station moving autonomously along a fixed path. Ray tracing is used with good success to compare the measurements in corridors with the results of simulations taking into account the main reflections along floors, ceilings and walls. Knife edge diffraction and geometric theory of diffraction are used to explain results of diffraction by corners. Results pertaining to the simulation of signal transmissions at 900 MHz in a single room are presented. The results show, for a sample of transmitter-receiver localizations, the effect of the different multipath rays, from which certain general conclusions can be drawn for improved system design.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Étiquettes directes de modèles (non validées)
Étiquettes de catégorie et de devis d'étude par modèle, issues des rondes d'étiquetage. C'est une sortie machine, non validée, et le désaccord entre modèles est livré comme donnée. Aucun devis ici n'est encore validé contre MEDLINE.
| Bras | Catégories | Devis d'étude | Confiance |
|---|---|---|---|
| gemma | aucune catégorie Domaine: non disponible · Genre: Empirique Porte sur le système de recherche canadien: non · Porte sur un sujet canadien: non | Simulation ou modélisation | low |
| gpt | aucune catégorie Domaine: non disponible · Genre: Empirique Porte sur le système de recherche canadien: non · Porte sur un sujet canadien: non | Simulation ou modélisation | low |
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéeÉtiqueté directement par 2 modèles lisant le dossier complet.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».