A small-body portable graphite calorimeter for dosimetry in low-energy clinical proton beams
Notice bibliographique
Résumé
Calorimetry has been recommended and performed in proton beams for some time, but never has graphite calorimetry been used as a reference dosimeter in clinical proton beams. Furthermore, only a few calorimetry measurements have been reported in ocular proton beams. In this paper we describe the construction and performance of a small-body portable graphite calorimeter for clinical low-energy proton beams. Perturbation correction factors for the gap effect, volume averaging effect, heat transfer phenomena and impurity effect are calculated and applied in a comparison with ionization chamber dosimetry following IAEA TRS-398. The ratio of absorbed dose to water obtained from the calorimeter measurements and from the ionization measurements varied between 0.983 and 1.019, depending on the beam type and the ionization chamber calibration modality. Standard uncertainties on these values varied between 1.9% and 2.5% including a substantial contribution from the kQ values in IAEA TRS-398. The (Wair/e)p values inferred from these measurements varied between 33.6 J C(-1) and 34.9 J C(-1) with similar standard uncertainties. A number of improvements for the small-body portable graphite calorimeter and the experimental set-up are suggested for potential reduction of the uncertainties.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».