A small-body portable graphite calorimeter for dosimetry in low-energy clinical proton beams
Bibliographic record
Abstract
Calorimetry has been recommended and performed in proton beams for some time, but never has graphite calorimetry been used as a reference dosimeter in clinical proton beams. Furthermore, only a few calorimetry measurements have been reported in ocular proton beams. In this paper we describe the construction and performance of a small-body portable graphite calorimeter for clinical low-energy proton beams. Perturbation correction factors for the gap effect, volume averaging effect, heat transfer phenomena and impurity effect are calculated and applied in a comparison with ionization chamber dosimetry following IAEA TRS-398. The ratio of absorbed dose to water obtained from the calorimeter measurements and from the ionization measurements varied between 0.983 and 1.019, depending on the beam type and the ionization chamber calibration modality. Standard uncertainties on these values varied between 1.9% and 2.5% including a substantial contribution from the kQ values in IAEA TRS-398. The (Wair/e)p values inferred from these measurements varied between 33.6 J C(-1) and 34.9 J C(-1) with similar standard uncertainties. A number of improvements for the small-body portable graphite calorimeter and the experimental set-up are suggested for potential reduction of the uncertainties.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".