A Time‐ and Angle‐Resolved X‐Ray Photoelectron Spectroscopy Study of Polystyrene Exposed to a Helium Plasma
Notice bibliographique
Résumé
Abstract Summary: Angle‐resolved X‐ray photoelectron spectroscopy (ARXPS) measurements were carried out, using Al Kα and Mg Kα radiation alternately, on a polystyrene sample that had been exposed to a helium plasma. It was observed that oxygen was introduced into the sample surface by the plasma treatment, and that some of it was lost over a period of 5 h under X‐ray irradiation in the vacuum of the spectrometer. The ARXPS data sets were corrected for the time displacement between consecutive measurements at different photoemission angles, and fitted with trapezoidal model depth profiles in order to extract simple oxygen concentration depth profiles, consistent with the data, as a function of time. The depth profiles were found to evolve in a consistent manner, indicating some loss of average concentration and especially thickness in the oxygen profile. In comparison with previously published results obtained using a helium/oxygen plasma, the oxygen loss was less severe. The results are also interpreted in terms of a model supposing the desorption of a highly oxidized oligomer layer created during the plasma exposure. Evolution of the apparent concentration of oxygen with Al Kα radiation as a function of irradiation time and photoemission angle. Symbols: ARXPS data; lines: splines drawn through points calculated from fitted depth profiles. magnified image Evolution of the apparent concentration of oxygen with Al Kα radiation as a function of irradiation time and photoemission angle. Symbols: ARXPS data; lines: splines drawn through points calculated from fitted depth profiles.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».