A comparative study of polystyrene decomposition in supercritical water and air environments using diamond anvil cell
Notice bibliographique
Résumé
Abstract Polystyrene (PS) decomposition in supercritical water (SCW) and in air was studied with the diamond anvil cell (DAC) technique coupled with microscopy and FTIR. Apparent concentrations were calculated by using digital imaging analysis. When PS + water systems (11.8–22.6 wt % PS) were rapidly heated at a rate of 2.3°C/s, the PS particle melted at 279.8–320.2°C. After formation of a globule at 409.3–452.5°C, the globule started to dissolve in color to yellow at 496.1°C. At 570.3°C and 742.5 MPa, solubility reached the maximum of 91.5 wt % (11.8 wt % PS). The soluble material was a styrenelike liquid, which was identified by IR after cooling. In isothermal runs at 400 and 450°C, two heterogeneous liquid phases consisting of water and decomposed PS were found. Styrenelike liquid products were identified after the reactions. PS decomposition stages in air consisted of melting, gas generation, liquid ring configuration, and finally yellow volatile products formation at 583.2°C. The results show conclusively that PS can be dissolved in SCW above 496.1°C and homogenous reaction is likely to occur above 570.3°C. Reactions in SCW at 400 and 450°C take place in heterogeneous liquid phases, while in the PS + air system, a formed liquid ring undergoes depolymerization. © 2001 John Wiley & Sons, Inc. J Appl Polym Sci 81: 3565–3577, 2001
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».