Bayesian Model for Calibration of ILI Tools
Notice bibliographique
Résumé
The Bayesian methodology is employed to calibrate the accuracy of high-resolution ILI tools for sizing metal-loss corrosion defects on pipelines by comparing the field-measured depths and ILI-reported depths for a set of static defects, i.e. defects that are recoated and ceased growing. The measurement error associated with the field-measuring tool is found to be negligibly small; therefore, the field-measured depth is assumed to equal the actual depth of the defect. The depth of a corrosion defect reported by an ILI tool is assumed to be a linear function of the corresponding field-measured depth subjected to a random scattering error. The probabilistic characteristics of the intercept and slope in the linear function, i.e. the constant and non-constant biases of the measurement error, as well as the standard deviation of the random scattering error are then quantified using the Bayesian methodology. The proposed methodology is able to calibrate the accuracies of multiple ILI tools simultaneously and quantify the potential correlations between the accuracies of different ILI tools. The methodology is illustrated using real ILI and field measurement data obtained on two pipelines currently in service.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,007 | 0,021 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,002 |
| Méta-épidémiologie (sens large) | 0,002 | 0,002 |
| Bibliométrie | 0,002 | 0,002 |
| Études des sciences et des technologies | 0,001 | 0,002 |
| Communication savante | 0,002 | 0,003 |
| Science ouverte | 0,004 | 0,002 |
| Intégrité de la recherche | 0,003 | 0,003 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,002 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».