Normal Multiple Auditory Steady-State Response Thresholds to Air-Conducted Stimuli in Infants
Notice bibliographique
Résumé
BACKGROUND AND PURPOSE: Multiple auditory steady-state responses (ASSRs) to stimuli modulated at approximately 80 Hz are a promising technique for threshold estimation in infants, but additional data are required. RESEARCH DESIGN: We obtained multiple ASSRs to air-conducted (AC) stimuli. STUDY SAMPLE: There were 54 children in two age groups: > six months (N=32) and < or = six months (N=22). All infants had normal hearing by tone-evoked auditory brain stem response. RESULTS: ASSR thresholds, estimated from 50 percent using cumulative percent present distributions, were 36, 30, 24, and 15 dB HL at 500, 1000, 2000, and 4000 Hz, respectively. Most (> or =90%) of the infants showed present ASSRs at 49, 45, 36, and 32 dB HL at 500, 1000, 2000, and 4000 Hz, respectively, with no differences in the results of younger versus older infants. When responses were present for all stimuli for both ears, most infants showed all eight responses within five minutes. Compared to ipsilateral responses, ASSRs in the contralateral EEG (electroencephalogram) channel were smaller and often absent. CONCLUSIONS: Based upon these data and the literature, normal AC ASSR "screening" levels would be 50, 45, 40, and 40 dB HL at 500, 1000, 2000, and 4000 Hz, respectively. Using the multiple-stimulus ASSR, infants with normal hearing referred for diagnostic electrophysiological threshold assessment can now be quickly confirmed as having normal thresholds for four frequencies in both ears.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,006 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».