Résumé
A prototype x-ray needle, which emits 62.5 kVp x-rays at the tip of a 20 cm long, 4 mm diameter steel needle, has been developed by Titan Pulse Sciences Incorporated (PSI) (Albuquerque, NM) and was tested for its suitability in brachytherapy applications in comparison with a similar device by the Photoelectron Corporation. The depth dose profiles were also compared with those of two common brachytherapy sources (125I and 192Ir). The depth dose characteristics of the radiation were comparable with the two brachytherapy sources with a slightly reduced attenuation gradient. The dose rate from the x-ray needle tip was relatively isotropic at the needle tip and was continuously adjustable over the range of 0 cGy min(-1) to upwards of 62 cGy min(-1) at a reference distance of 1 cm in air. We detected a significant proportion of x-rays generated along the needle shaft, and not at the needle tip, as intended. The energy spectrum emitted from this device had a peak intensity at 21 keV and an average energy of 28 keV. The beam was attenuated in both aluminium (the first half-value layer being less than 0.1 mm) and in water (50% dose at approximately 2 mm). These studies confirm that although there is potential for a system similar to this one for clinical applications, the simplistic electron guidance used in this particular prototype device limits it to research applications. Further optimization is required in focusing and steering the electron beam to the target, improving x-ray production efficiency and using x-ray target cooling to achieve higher dose rates.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».