MétaCan
Menu
Back to cohort
Record W2013982251 · doi:10.1088/0031-9155/46/1/307

Operational characteristics of a prototype x-ray needle device

2000· article· en· W2013982251 on OpenAlexafffund
S Karnas, Nikita Avvakumov, Edward Yu, Jerry Battista

Bibliographic record

VenuePhysics in Medicine and Biology · 2000
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsOccupational Cancer Research CentreWestern University
FundersRyerson University
KeywordsComputer scienceMaterials scienceMedical physicsPhysics

Abstract

fetched live from OpenAlex

A prototype x-ray needle, which emits 62.5 kVp x-rays at the tip of a 20 cm long, 4 mm diameter steel needle, has been developed by Titan Pulse Sciences Incorporated (PSI) (Albuquerque, NM) and was tested for its suitability in brachytherapy applications in comparison with a similar device by the Photoelectron Corporation. The depth dose profiles were also compared with those of two common brachytherapy sources (125I and 192Ir). The depth dose characteristics of the radiation were comparable with the two brachytherapy sources with a slightly reduced attenuation gradient. The dose rate from the x-ray needle tip was relatively isotropic at the needle tip and was continuously adjustable over the range of 0 cGy min(-1) to upwards of 62 cGy min(-1) at a reference distance of 1 cm in air. We detected a significant proportion of x-rays generated along the needle shaft, and not at the needle tip, as intended. The energy spectrum emitted from this device had a peak intensity at 21 keV and an average energy of 28 keV. The beam was attenuated in both aluminium (the first half-value layer being less than 0.1 mm) and in water (50% dose at approximately 2 mm). These studies confirm that although there is potential for a system similar to this one for clinical applications, the simplistic electron guidance used in this particular prototype device limits it to research applications. Further optimization is required in focusing and steering the electron beam to the target, improving x-ray production efficiency and using x-ray target cooling to achieve higher dose rates.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.078
GPT teacher head0.335
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2000
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced X-ray and CT ImagingFrench-language works237,207