X-ray irradiation induced changes in electron transport in stabilized a-Se photoconductors
Notice bibliographique
Résumé
We have examined the effect of high-dose x-ray irradiation on electron transport in stabilized amorphous selenium (a-Se) x-ray photoconductive films (of the type used in x-ray image detectors) by measuring the electron lifetime τe through interrupted-field time-of-flight experiments. X-ray induced effects have been examined through two types of experiments. In recovery experiments, the a-Se was preirradiated with and without an applied field (5 V/μm) during irradiation with sufficient dose (typically ∼20 Gy at 21 °C) to significantly reduce the electron lifetime by ∼50%, and then the recovery of the lifetime was monitored as a function of time at three different temperatures, 10 °C, 21 °C, and 35 °C. The lifetime recovery kinetics was exponential with a relaxation time τr that is thermally activated with an activation energy of 1.66 eV. τr is a few hours at 21 °C and only a few minutes at 35 °C. In experiments examining the irradiation induced effects, the a-Se film was repeatedly exposed to x-ray radiation and the changes in the drift mobility and lifetime were monitored as a function of accumulated dose D. There was no observable change in the drift mobility. At 21 °C, the concentration of x-ray induced deep traps (or capture centers), Nd, increases linearly with D (Nd ∼ D) whereas at 35 °C, the recovery process prevents a linear increase in Nd with D, and Nd saturates. In all cases, even under high dose irradiation (∼50 Gy), the lifetime was recoverable to its original equilibrium (pre-exposure) value within a few relaxation times.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».