MétaCan
Menu
Back to cohort
Record W2018373340 · doi:10.1063/1.4839935

X-ray irradiation induced changes in electron transport in stabilized a-Se photoconductors

2013· article· en· W2018373340 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueJournal of Applied Physics · 2013
Typearticle
Languageen
FieldMaterials Science
TopicPhase-change materials and chalcogenides
Canadian institutionsUniversity of Saskatchewan
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsIrradiationElectronKineticsX-rayAmorphous solidMaterials scienceElectron beam processingRadiation damagePhotoconductivityAnalytical Chemistry (journal)ChemistryAtomic physicsPhysicsOptoelectronicsOpticsCrystallographyNuclear physics

Abstract

fetched live from OpenAlex

We have examined the effect of high-dose x-ray irradiation on electron transport in stabilized amorphous selenium (a-Se) x-ray photoconductive films (of the type used in x-ray image detectors) by measuring the electron lifetime τe through interrupted-field time-of-flight experiments. X-ray induced effects have been examined through two types of experiments. In recovery experiments, the a-Se was preirradiated with and without an applied field (5 V/μm) during irradiation with sufficient dose (typically ∼20 Gy at 21 °C) to significantly reduce the electron lifetime by ∼50%, and then the recovery of the lifetime was monitored as a function of time at three different temperatures, 10 °C, 21 °C, and 35 °C. The lifetime recovery kinetics was exponential with a relaxation time τr that is thermally activated with an activation energy of 1.66 eV. τr is a few hours at 21 °C and only a few minutes at 35 °C. In experiments examining the irradiation induced effects, the a-Se film was repeatedly exposed to x-ray radiation and the changes in the drift mobility and lifetime were monitored as a function of accumulated dose D. There was no observable change in the drift mobility. At 21 °C, the concentration of x-ray induced deep traps (or capture centers), Nd, increases linearly with D (Nd ∼ D) whereas at 35 °C, the recovery process prevents a linear increase in Nd with D, and Nd saturates. In all cases, even under high dose irradiation (∼50 Gy), the lifetime was recoverable to its original equilibrium (pre-exposure) value within a few relaxation times.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.012
Threshold uncertainty score0.580

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.265
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it