Design and evaluation of an external high‐current target for production of <sup>211</sup>At
Notice bibliographique
Résumé
This report presents the design and testing of an external target system for clinical‐scale production of 211 At on the Scanditronix MC‐50 cyclotron at the University of Washington Medical Center. While other 211 At production sites have typically employed an internal target, an external target setup was deemed necessary at our facility since the cyclotron's main application is for cancer patient treatment via fast neutron therapy. The challenge was that previous external 211 At targets demonstrated reduced yields when compared to internal target systems. The target developed in this study has been used in more than 100 irradiations. From those irradiations 211 At saturated yields of 181 ± 16 MBq/μA and 241 ± 17 MBq/μA at 28.0 and 29.0 MeV, respectively, were obtained. Importantly, consistent yields were observed over the 25–60 μA range of irradiation currents evaluated. With a recent production in excess of 4 GBq 211 At for a 29.0 MeV, 58 μA, 4‐hour irradiation, this external target system has demonstrated its potential for producing clinically relevant quantities of 211 At.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».