Distribution Grid Voltage Control Using Cascaded Multi-level Inverter-based Static Synchronous Compensator
Notice bibliographique
Résumé
In this article, the voltage control performance of the cascaded multi-level inverter based static synchronous compensator was studied, specifically, a 21-level cascaded multi-level inverter based static synchronous compensator was considered. The switching angles of the cascaded multi-level inverter based static synchronous compensator have been determined by an optimization methodology based on the sequential quadratic programming technique for minimizing the total harmonic distortion of the static synchronous compensator output voltage. To achieve satisfactory performance of the static synchronous compensator voltage controller, two different fuzzy logic control schemes, namely, indirect and direct control systems, have been developed. The performances of these two developed control schemes for controlling the bus voltage were investigated with detailed non-linear fault simulation studies in a practical power distribution system using PSCAD/EMTDC (Manitoba HVDC Research Center, Winnipeg, Manitoba, Canada) software and have been found satisfactory. Furthermore, the performances of the proposed fuzzy controllers have also been found to be superior to that obtained with an indirect proportional-integral controller.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».