Comparison of dosimetry calibration factors at the NRCC and the NIST
Notice bibliographique
Résumé
In early 1998, three transfer ionization chambers were used to compare the air-kerma and absorbed-dose-to-water calibration factors measured by the National Research Council of Canada (NRCC) and the National Institute of Standards and Technology (NIST). The ratios between the NRCC and NIST calibration factors are 0.9950 and 1.0061 in the case of the absorbed-dose-to-water and air-kerma standards, respectively. In the case of the standard of absorbed dose to water, the combined uncertainty of the ratio between the standards of the two laboratories is about 0.6% and consequently, the observed difference of 0.5% is not significant at the one sigma level. In the case of the standard of air kerma, the combined uncertainty of the ratio between the standards of the two laboratories is about 0.4%, and so the observed difference of 0.61% is significant at the one sigma level. However, this discrepancy is due to the known differences in the methods of assessing the wall correction factor at the two laboratories. Taking into account changes implemented in the standards that form the basis of the calibrations, the present results are consistent with those of the previous comparison done in 1990/91. As a direct result of these differences in the calibration factors, changing from an air-kerma based protocol following TG-21 to an absorbed-dose-to-water based protocol following TG-51, would alter the relationship between clinical dosimetry in Canada and the United States by about 1%. For clinical reference dosimetry, the change from TG-21 to TG-51 could result in an increase of up to 2% depending upon the ion chamber used, the details of the protocol followed and the source of traceability, either NRCC or NIST.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».