MétaCan
Menu
Back to cohort
Record W2038456567 · doi:10.1118/1.599031

Comparison of dosimetry calibration factors at the NRCC and the NIST

2000· article· en· W2038456567 on OpenAlexaffabout
K R Shortt, J. Shobe, Steve R. Domen

Bibliographic record

VenueMedical Physics · 2000
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsNational Research Council Canada
FundersNational Institute of Standards and Technology
KeywordsKermaNISTDosimetryCalibrationAbsorbed doseEnvironmental sciencePrimary standardIonization chamberNuclear medicineProtocol (science)StatisticsMathematicsPhysicsIonizationMedicineComputer science

Abstract

fetched live from OpenAlex

In early 1998, three transfer ionization chambers were used to compare the air-kerma and absorbed-dose-to-water calibration factors measured by the National Research Council of Canada (NRCC) and the National Institute of Standards and Technology (NIST). The ratios between the NRCC and NIST calibration factors are 0.9950 and 1.0061 in the case of the absorbed-dose-to-water and air-kerma standards, respectively. In the case of the standard of absorbed dose to water, the combined uncertainty of the ratio between the standards of the two laboratories is about 0.6% and consequently, the observed difference of 0.5% is not significant at the one sigma level. In the case of the standard of air kerma, the combined uncertainty of the ratio between the standards of the two laboratories is about 0.4%, and so the observed difference of 0.61% is significant at the one sigma level. However, this discrepancy is due to the known differences in the methods of assessing the wall correction factor at the two laboratories. Taking into account changes implemented in the standards that form the basis of the calibrations, the present results are consistent with those of the previous comparison done in 1990/91. As a direct result of these differences in the calibration factors, changing from an air-kerma based protocol following TG-21 to an absorbed-dose-to-water based protocol following TG-51, would alter the relationship between clinical dosimetry in Canada and the United States by about 1%. For clinical reference dosimetry, the change from TG-21 to TG-51 could result in an increase of up to 2% depending upon the ion chamber used, the details of the protocol followed and the source of traceability, either NRCC or NIST.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.013
metaresearch head score (Gemma)0.029
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.842
Threshold uncertainty score0.315

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0130.029
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.003
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.307
Teacher spread0.296 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2000
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207