Field emission characteristics of a lanthanum monosulfide cold cathode array fabricated using microelectromechanical systems technology
Notice bibliographique
Résumé
Using microelectromechanical systems technology, an array of cold cathodes was fabricated by pulsed laser deposition of chemically and thermally stable lanthanum monosulfide (LaS) thin film anode and cathode contacts. The latter were defined via etching and processing of two different pieces of (100) Si wafers separated via a highly resistive sputter deposited aluminum nitride (AlN) layer, whose thickness was used to control the anode to cathode spacing. The top and bottom Si wafers were aligned and glued together using high temperature, vacuum compatible epoxy. Field emission characteristics were recorded in a vacuum chamber with a base pressure less than 10−7Torr. An average electric field threshold for Fowler-Nordheim field emission in the range of 100V∕μm was measured. The largest emission current measured was about 5×10−7A, above which thermal runaway occurred, leading to a failure of the cathode. The failure mechanism is analyzed in terms of a patchwork field emission model from the LaS thin film reported recently. Suggestions for improvements in the cathode design are discussed.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».