Expandable Metal Biliary Stenting in Patients With Recurrent Premature Polyethylene Stent Occlusion
Notice bibliographique
Résumé
OBJECTIVES: Expandable metal stents are currently used to treat biliary tract obstruction. Few data exist on the role of metal stents in patients with recurrent premature plastic biliary stent occlusion. We report our preliminary results using an expandable metal biliary stent with enhanced stent flexibility in this group of patients. Our aim was to assess the efficacy of the Diamond biliary stent in the treatment of recurrent premature biliary plastic stent blockage. METHODS: From September 1997 to June 1998, six patients with inoperable biliary obstruction and at least one prior episode of plastic stent occlusion were treated with an expandable metal biliary prosthesis. There were four women and six men, with a mean age of 73+/-11 yr. Five patients had malignant biliary obstruction, and one inoperable patient had a biliary stricture secondary to chronic pancreatitis. Patients were followed-up prospectively until either stent occlusion or death. The patency duration of the metal stents was compared to that of the most recently placed plastic stents. RESULTS: All stents were successfully inserted endoscopically with visualized biliary drainage. No significant immediate postprocedural complications were noted. Median time from initial diagnosis of biliary obstruction to metal stent insertion was 35 wk (range 7-142), during which time patients had occluded a median of 4.5 plastic stents (range 2-5). Median patient survival was 117 days (15-312) and median time to blockage of the last plastic stent was 25.5 days (range 10-90 days). Three cases of metal stent occlusion occurred. One patient had early stent occlusion at 9 days because of debris and sludge clogging the metal stent. Two other patients developed stent occlusion at 120 and 157 days. Two stents remained patent until the patients' deaths at 15 and 87 days. Overall median stent patency was 139 days. The three patients who developed stent occlusion were treated with successful insertion of one or more plastic stents through the existing metal stent. Duration of metal stent patency was significantly longer than that of the last plastic stent (58.8 days longer; 95% CI [6.4, 111]; p = 0.03). CONCLUSIONS: Metal biliary prostheses represent an effective management strategy for recurrent plastic biliary stent obstruction. Patients in this subgroup may have a shorter duration of metal stent patency than the reported duration of stent patency in patients receiving initial metal stent placement. However the duration of patency still seems to be significantly longer than that of the most recently placed plastic stent.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».