MétaCan
Menu
Back to cohort

Expandable Metal Biliary Stenting in Patients With Recurrent Premature Polyethylene Stent Occlusion

2001· article· en· W2054759293 on OpenAlexaff
Krishna Menon, Joseph Romagnuolo, Alan Barkun

Bibliographic record

VenueThe American Journal of Gastroenterology · 2001
Typearticle
Languageen
FieldMedicine
TopicGallbladder and Bile Duct Disorders
Canadian institutionsMcGill University Health Centre
Fundersnot available
KeywordsMedicineStentOcclusionSurgeryBiliary tractPancreatitisRadiology

Abstract

fetched live from OpenAlex

OBJECTIVES: Expandable metal stents are currently used to treat biliary tract obstruction. Few data exist on the role of metal stents in patients with recurrent premature plastic biliary stent occlusion. We report our preliminary results using an expandable metal biliary stent with enhanced stent flexibility in this group of patients. Our aim was to assess the efficacy of the Diamond biliary stent in the treatment of recurrent premature biliary plastic stent blockage. METHODS: From September 1997 to June 1998, six patients with inoperable biliary obstruction and at least one prior episode of plastic stent occlusion were treated with an expandable metal biliary prosthesis. There were four women and six men, with a mean age of 73+/-11 yr. Five patients had malignant biliary obstruction, and one inoperable patient had a biliary stricture secondary to chronic pancreatitis. Patients were followed-up prospectively until either stent occlusion or death. The patency duration of the metal stents was compared to that of the most recently placed plastic stents. RESULTS: All stents were successfully inserted endoscopically with visualized biliary drainage. No significant immediate postprocedural complications were noted. Median time from initial diagnosis of biliary obstruction to metal stent insertion was 35 wk (range 7-142), during which time patients had occluded a median of 4.5 plastic stents (range 2-5). Median patient survival was 117 days (15-312) and median time to blockage of the last plastic stent was 25.5 days (range 10-90 days). Three cases of metal stent occlusion occurred. One patient had early stent occlusion at 9 days because of debris and sludge clogging the metal stent. Two other patients developed stent occlusion at 120 and 157 days. Two stents remained patent until the patients' deaths at 15 and 87 days. Overall median stent patency was 139 days. The three patients who developed stent occlusion were treated with successful insertion of one or more plastic stents through the existing metal stent. Duration of metal stent patency was significantly longer than that of the last plastic stent (58.8 days longer; 95% CI [6.4, 111]; p = 0.03). CONCLUSIONS: Metal biliary prostheses represent an effective management strategy for recurrent plastic biliary stent obstruction. Patients in this subgroup may have a shorter duration of metal stent patency than the reported duration of stent patency in patients receiving initial metal stent placement. However the duration of patency still seems to be significantly longer than that of the most recently placed plastic stent.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.033
Threshold uncertainty score0.346

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.234
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2001
Admission routes1
Has abstractyes

Explore more