Initial investigation on the use of MR spectroscopy and micro‐MRI of GAFCHROMIC<sup>®</sup> EBT radiotherapy film
Notice bibliographique
Résumé
PURPOSE: This article presents an initial investigation of the efficacy of using 1H MRS and micro-MRI as analysis techniques for irradiated GAFCHROMIC EBT radiotherapy films. METHODS: GAFCHROMIC EBT radiotherapy film was irradiated with 6 MV x rays to known doses ranging from 5 to 1000 cGy. 24 h following irradiation 1H MRS measurements were performed to access the degree of post-irradiation polymer cross-linking. 2D 1H micro-MRI experiments were also performed for film irradiations of 0 and 300 cGy. RESULTS: Linear response of the 1H MRS linewidth to dose in the range from 0 to 400 cGy (R2 = 0.98) was observed. Such linearity is not seen when analyzed under conventional light analysis. The sensitivity of the film, as measured by the slope of the curve between 0 and 400 cGy, is 0.0042 +/- 0.0003 kHz/cGy, demonstrating the sensitivity of the 1H MRS technique used to analyze the film. The film saturates at a dose of approximately 900 cGy. Broadline 1H MRS provides a quantitative measure of the degree of polymerization of the film. CONCLUSIONS: A quantitative measurement of the degree of polymerization of GAFCHROMIC EBT film has been presented using 1H MRS. The saturation of the film at approximately 900 cGy is corroborated by that observed with light analysis. Further MR spectroscopic experiments are needed to investigate the response of the film to dose, allowing for a better understanding of the relationship between polymer cross-linking in the active layer.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».