MétaCan
Menu
← Back to cohort
Record W2061456492 · doi:10.1118/1.3242216

Initial investigation on the use of MR spectroscopy and micro‐MRI of GAFCHROMIC<sup>®</sup> EBT radiotherapy film

2009· article· en· W2061456492 on OpenAlexaff
R. Holly, Brian Keller, Jean‐Philippe Pignol, Claude Lemaire, H. Peemoeller

Bibliographic record

VenueMedical Physics · 2009
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of WaterlooHealth Sciences CentreSunnybrook Health Science Centre
Fundersnot available
KeywordsMaterials scienceIrradiationLaser linewidthDosimetryRadiationNuclear medicineOpticsNuclear magnetic resonanceMedicinePhysicsNuclear physicsLaser

Abstract

fetched live from OpenAlex

PURPOSE: This article presents an initial investigation of the efficacy of using 1H MRS and micro-MRI as analysis techniques for irradiated GAFCHROMIC EBT radiotherapy films. METHODS: GAFCHROMIC EBT radiotherapy film was irradiated with 6 MV x rays to known doses ranging from 5 to 1000 cGy. 24 h following irradiation 1H MRS measurements were performed to access the degree of post-irradiation polymer cross-linking. 2D 1H micro-MRI experiments were also performed for film irradiations of 0 and 300 cGy. RESULTS: Linear response of the 1H MRS linewidth to dose in the range from 0 to 400 cGy (R2 = 0.98) was observed. Such linearity is not seen when analyzed under conventional light analysis. The sensitivity of the film, as measured by the slope of the curve between 0 and 400 cGy, is 0.0042 +/- 0.0003 kHz/cGy, demonstrating the sensitivity of the 1H MRS technique used to analyze the film. The film saturates at a dose of approximately 900 cGy. Broadline 1H MRS provides a quantitative measure of the degree of polymerization of the film. CONCLUSIONS: A quantitative measurement of the degree of polymerization of GAFCHROMIC EBT film has been presented using 1H MRS. The saturation of the film at approximately 900 cGy is corroborated by that observed with light analysis. Further MR spectroscopic experiments are needed to investigate the response of the film to dose, allowing for a better understanding of the relationship between polymer cross-linking in the active layer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.288
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→