Wind and tall buildings: negatives and positives
Notice bibliographique
Résumé
Abstract Wind is often regarded as the foe of tall buildings since it tends to be the governing lateral load. Careful aerodynamic design of tall buildings through wind tunnel testing can greatly reduce wind loads and their affect on building motions. Various shaping strategies are discussed, aimed particularly at suppression of vortex shedding since it is frequently the cause of crosswind excitation. The use of supplementary damping systems is another approach that takes the energy out of building motions and reduces loads. Different applications of damping systems are described on several buildings, and an example of material savings and reduced carbon emissions is given. Wind also has some potential beneficial effects particularly to tall buildings. One is that, since wind speeds are higher at the heights of tall buildings, the potential for extracting wind energy using wind turbines is significantly improved compared with ground level. This paper explores how much energy might be generated in this way relative to the building's energy usage. Other benefits are to be found in judicious use of natural ventilation, sometimes involving double‐layer wall systems, and, in hot climates, the combination of tailored wind and shade conditions to improve outdoor comfort near tall buildings and on balconies and terraces. Copyright © 2008 John Wiley & Sons, Ltd.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,004 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,002 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,006 |
| Communication savante | 0,003 | 0,005 |
| Science ouverte | 0,001 | 0,002 |
| Intégrité de la recherche | 0,002 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,010 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».