Anterior Cervical Plate Fixation: A Biomechanical Study to Evaluate the Effects of Plate Design, Endplate Preparation, and Bone Mineral Density
Notice bibliographique
Résumé
STUDY DESIGN: A biomechanical study using multidirectional flexibility testing in a human cadaveric cervical spine model of a flexion-distraction injury. OBJECTIVES: To compare the immediate postoperative stabilizing effect of dynamic and rigid anterior cervical plates and to assess the confounding effects of bone mineral density (BMD) and endplate preparation technique. SUMMARY OF BACKGROUND DATA: Dynamic plate designs presumably increase load sharing between the plate and graft, but their effect on spinal stabilization has not been assessed in a traumatic flexion-distraction model. METHODS: Twenty-four fresh frozen human cervical functional spinal units were dual-energy x-ray absorptiometry scanned for bone mineral density and allocated into 4 groups by the type of plate, dynamic (ABC, Aesculap, Germany) versus rigid (Cervical Spine Locking Plate, Synthes USA, Paoli, PA), and the technique of endplate preparation, intact versus removed. Each functional spinal unit had all posterior ligaments transected and both inferior facets excised, after which anterior discectomy, grafting, and plating was performed. Nondestructive testing applied a 1.5 Nm pure moment, whereas ranges of motion and neutral zones were measured in flexion/extension, lateral bending, and rotation. Ratios of the range of motion and neutral zone of the plated to the intact site were analyzed. The load sharing between the plate and the functional spinal unit was measured via strain gauges mounted on the plate. RESULTS: There were no significant differences in the range of motion or neutral zone ratios between the 2 plate designs, except for the range of motion ratio in extension, where the dynamic plate exhibited better stabilization than the rigid plate (P = 0.02). There was a consistent interaction whereby endplate removal resulted in better stabilization for the dynamic plate, but less stabilization for the rigid plate. Significantly less motion was observed with increasing bone mineral density in all loading directions. In flexion and extension, the dynamic plate measured one-third less strain than the rigid plate. CONCLUSIONS: The dynamic plate appeared to provide better stabilization in extension, and the technique of endplate preparation has some effect on immediate stabilization, dependent on the type of plate employed. Bone mineral density of the specimen was a strong determinant of the degree of stabilization achieved, regardless of the type of plate used.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».