Anterior Cervical Plate Fixation: A Biomechanical Study to Evaluate the Effects of Plate Design, Endplate Preparation, and Bone Mineral Density
Bibliographic record
Abstract
STUDY DESIGN: A biomechanical study using multidirectional flexibility testing in a human cadaveric cervical spine model of a flexion-distraction injury. OBJECTIVES: To compare the immediate postoperative stabilizing effect of dynamic and rigid anterior cervical plates and to assess the confounding effects of bone mineral density (BMD) and endplate preparation technique. SUMMARY OF BACKGROUND DATA: Dynamic plate designs presumably increase load sharing between the plate and graft, but their effect on spinal stabilization has not been assessed in a traumatic flexion-distraction model. METHODS: Twenty-four fresh frozen human cervical functional spinal units were dual-energy x-ray absorptiometry scanned for bone mineral density and allocated into 4 groups by the type of plate, dynamic (ABC, Aesculap, Germany) versus rigid (Cervical Spine Locking Plate, Synthes USA, Paoli, PA), and the technique of endplate preparation, intact versus removed. Each functional spinal unit had all posterior ligaments transected and both inferior facets excised, after which anterior discectomy, grafting, and plating was performed. Nondestructive testing applied a 1.5 Nm pure moment, whereas ranges of motion and neutral zones were measured in flexion/extension, lateral bending, and rotation. Ratios of the range of motion and neutral zone of the plated to the intact site were analyzed. The load sharing between the plate and the functional spinal unit was measured via strain gauges mounted on the plate. RESULTS: There were no significant differences in the range of motion or neutral zone ratios between the 2 plate designs, except for the range of motion ratio in extension, where the dynamic plate exhibited better stabilization than the rigid plate (P = 0.02). There was a consistent interaction whereby endplate removal resulted in better stabilization for the dynamic plate, but less stabilization for the rigid plate. Significantly less motion was observed with increasing bone mineral density in all loading directions. In flexion and extension, the dynamic plate measured one-third less strain than the rigid plate. CONCLUSIONS: The dynamic plate appeared to provide better stabilization in extension, and the technique of endplate preparation has some effect on immediate stabilization, dependent on the type of plate employed. Bone mineral density of the specimen was a strong determinant of the degree of stabilization achieved, regardless of the type of plate used.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".