MétaCan
Menu
Back to cohort

Anterior Cervical Plate Fixation: A Biomechanical Study to Evaluate the Effects of Plate Design, Endplate Preparation, and Bone Mineral Density

2005· article· en· W2083343938 on OpenAlexaff
Marcel F. Dvorak, Tobias Pitzen, Qingan Zhu, Jeff D. Gordon, Charles G. Fisher, Thomas R. Oxland

Bibliographic record

VenueSpine · 2005
Typearticle
Languageen
FieldMedicine
TopicCervical and Thoracic Myelopathy
Canadian institutionsVancouver Hospital and Health Sciences Centre
Fundersnot available
KeywordsCadaveric spasmMedicineRange of motionBone mineralBiomechanicsOrthodonticsDiscectomyCadaverAnterior cervical discectomy and fusionBone densityAnatomyBiomedical engineeringSurgeryCervical spineOsteoporosisLumbar

Abstract

fetched live from OpenAlex

STUDY DESIGN: A biomechanical study using multidirectional flexibility testing in a human cadaveric cervical spine model of a flexion-distraction injury. OBJECTIVES: To compare the immediate postoperative stabilizing effect of dynamic and rigid anterior cervical plates and to assess the confounding effects of bone mineral density (BMD) and endplate preparation technique. SUMMARY OF BACKGROUND DATA: Dynamic plate designs presumably increase load sharing between the plate and graft, but their effect on spinal stabilization has not been assessed in a traumatic flexion-distraction model. METHODS: Twenty-four fresh frozen human cervical functional spinal units were dual-energy x-ray absorptiometry scanned for bone mineral density and allocated into 4 groups by the type of plate, dynamic (ABC, Aesculap, Germany) versus rigid (Cervical Spine Locking Plate, Synthes USA, Paoli, PA), and the technique of endplate preparation, intact versus removed. Each functional spinal unit had all posterior ligaments transected and both inferior facets excised, after which anterior discectomy, grafting, and plating was performed. Nondestructive testing applied a 1.5 Nm pure moment, whereas ranges of motion and neutral zones were measured in flexion/extension, lateral bending, and rotation. Ratios of the range of motion and neutral zone of the plated to the intact site were analyzed. The load sharing between the plate and the functional spinal unit was measured via strain gauges mounted on the plate. RESULTS: There were no significant differences in the range of motion or neutral zone ratios between the 2 plate designs, except for the range of motion ratio in extension, where the dynamic plate exhibited better stabilization than the rigid plate (P = 0.02). There was a consistent interaction whereby endplate removal resulted in better stabilization for the dynamic plate, but less stabilization for the rigid plate. Significantly less motion was observed with increasing bone mineral density in all loading directions. In flexion and extension, the dynamic plate measured one-third less strain than the rigid plate. CONCLUSIONS: The dynamic plate appeared to provide better stabilization in extension, and the technique of endplate preparation has some effect on immediate stabilization, dependent on the type of plate employed. Bone mineral density of the specimen was a strong determinant of the degree of stabilization achieved, regardless of the type of plate used.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.708
Threshold uncertainty score0.473

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.316
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations84
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicCervical and Thoracic MyelopathyFrench-language works237,207