Low dark current and high dynamic range a-Si:H MSM photodetector for large area medical imaging
Notice bibliographique
Résumé
Previously a-Si:H metal-semiconductor-metal (MSM) lateral detectors for indirect medical imaging applications had been proposed by our research group. These lateral detectors are attractive due to their ease of fabrication primarily because there is no p+ doped semiconductor layer, thus making it compatible with industry standard amorphous silicon thin film transistor electronics processing. However the earlier devices exhibited high dark current which is problematic for integration mode imaging. In the other words, they were limited in term of dynamic range. In this study, we demonstrate an a-Si:H MSM lateral structure with low dark current, high dynamic range and comparable sensitivity and quantum efficiency to conventional p-i-n photodiodes. These improvements are achieved by the introduction of a thin polymer layer as a blocking contact. The fabricated amorphous silicon based MSM detector exhibits a photo-response of more than 3 orders of magnitude to a green light source (λ = 525nm). In comparison to vertical p-i-n structures, the reported MSM lateral devices show gains in terms of dynamic range, ease of fabrication (no p+ layer), faster speed at the cost of a slightly reduced quantum efficiency. The experimental results of dark and photocurrent measurements as well as the responsivity for two in-house fabricated MSM structures at different bias voltages and light intensity are presented. This results are promising and encourage the development of a-Si:H lateral MSM devices for indirect conversion large area medical imaging applications and especially low cost flat panel computed tomography.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».