Low dark current and high dynamic range a-Si:H MSM photodetector for large area medical imaging

2013· article· en· W2087417401 on OpenAlexafffund
Sina Ghanbarzadeh, Shiva Abbaszadeh, Michael M. Adachi, Karim S. Karim

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2013
Typearticle
Languageen
FieldEngineering
TopicThin-Film Transistor Technologies
Canadian institutionsUniversity of TorontoUniversity of Waterloo
FundersGovernment of Canada
KeywordsDark currentOptoelectronicsMaterials scienceResponsivityPhotodetectorPhotodiodePhotocurrentQuantum efficiencyDynamic rangeAmorphous siliconDetectorWide dynamic rangeOpticsSiliconCrystalline siliconPhysics

Abstract

fetched live from OpenAlex

Previously a-Si:H metal-semiconductor-metal (MSM) lateral detectors for indirect medical imaging applications had been proposed by our research group. These lateral detectors are attractive due to their ease of fabrication primarily because there is no p+ doped semiconductor layer, thus making it compatible with industry standard amorphous silicon thin film transistor electronics processing. However the earlier devices exhibited high dark current which is problematic for integration mode imaging. In the other words, they were limited in term of dynamic range. In this study, we demonstrate an a-Si:H MSM lateral structure with low dark current, high dynamic range and comparable sensitivity and quantum efficiency to conventional p-i-n photodiodes. These improvements are achieved by the introduction of a thin polymer layer as a blocking contact. The fabricated amorphous silicon based MSM detector exhibits a photo-response of more than 3 orders of magnitude to a green light source (λ = 525nm). In comparison to vertical p-i-n structures, the reported MSM lateral devices show gains in terms of dynamic range, ease of fabrication (no p+ layer), faster speed at the cost of a slightly reduced quantum efficiency. The experimental results of dark and photocurrent measurements as well as the responsivity for two in-house fabricated MSM structures at different bias voltages and light intensity are presented. This results are promising and encourage the development of a-Si:H lateral MSM devices for indirect conversion large area medical imaging applications and especially low cost flat panel computed tomography.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.812
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.211
Teacher spread0.205 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicThin-Film Transistor TechnologiesFrench-language works237,207