Cochrane in CORR ®: Intramedullary Nails for Extracapsular Hip Fractures in Adults (Review)

2015· review· en· W2094843074 sur OpenAlexaff
Nathan Evaniew, Mohit Bhandari

Notice bibliographique

RevueClinical Orthopaedics and Related Research · 2015
Typereview
Langueen
DomaineMedicine
ThématiqueHip and Femur Fractures
Établissements canadiensMcMaster University
Organismes subventionnairesnon disponible
Mots-clésMedicineIntramedullary rodSurgeryInternal fixationOrthopedic surgeryFixation (population genetics)Dynamic hip screwPopulation

Résumé

récupéré en direct d'OpenAlex

Importance of the Topic More than 1.5 million patients suffer hip fractures worldwide each year [3], and annual direct and indirect costs are projected to exceed USD 130 billion globally by 2050 [6]. Thirty-day mortality approaches 5% in males and 9% in females, and many more patients experience significant functional loss and debilitation [4]. Approximately 50% of all hip fractures are extracapsular, which surgeons can treat using a wide variety of possible internal fixation strategies. Extramedullary sliding hip screws were the standard of care from the 1950s to the 1990s, but many surgeons now prefer intramedullary nails that interlock proximally in the femoral head [2]. There has been a more than 20-fold relative increase in the utilization of intramedullary nails since 1999, and approximately two-thirds of new orthopaedic surgeons now select them routinely [1]. Several designs are on the market from different manufacturers, each varying in length, diameter, neck-shaft angle, number of locking screws or blades, ability to slide and/or compress, ability to control rotation, construction materials, start-point, and surgical technique. This review aimed to determine whether different nail designs are associated with unique benefits or harms in patients with extracapsular hip fractures. Twelve designs were evaluated among 2130 patients from 17 separate trials. The authors concluded that there were no important differences in function, mobility, pain, death, fracture fixation complications, or rates of revision surgery between most of the implants that were studied. Upon Closer Inspection Extracapsular hip fractures include pertrochanteric simple fractures (AO classification 31-A1), pertrochanteric multifragmentary fractures (31-A2), intertrochanteric fractures (31-A3), and subtrochanteric fractures (32-A/B/C [1-3].1). Reverse obliquity intertrochanteric fractures, intertrochanteric fractures with subtrochanteric extension, and subtrochanteric fractures each carry a worse prognosis than A1 or A2 fractures [7, 8], and unequal inclusion of patients with these fractures in the primary trials could bias the pooled results towards worse outcomes for the treatment group that has more of them. In order to avoid this problem, the authors attempted to separate the results for patients with subtrochanteric fractures from the results for patients with intertrochanteric and pertrochanteric fractures. These types of secondary analyses are commonly referred to as a subgroup analyses and they are frequently used to address specific questions about particular patient groups, types of intervention, or types of study designs. There are two important ways that subgroup analyses can be problematic. First, subgroup analyses are rarely powered adequately, which leaves them at risk of failing to identify important differences between treatment groups (Type II error). Second, testing multiple subgroups raises the possibility of identifying spurious but statistically significant differences due to chance alone, simply because there have been more “rolls of the dice” (Type I error) [11]. Readers can distinguish credible from less-credible subgroup claims by looking for hypotheses that were formulated before collecting the data, are supported by background literature and/or biological rationale, and are consistent across studies. The direction of a potential subgroup effect should be also prespecified and only a small number of carefully considered hypotheses should be considered. The proposed subgroup for subtrochanteric fractures met many of these criteria, but there was insufficient data in the primary trials to test it. As such, this meta-analysis does not inform whether certain nails might be better suited to specific fractures [9]. Take-Home Messages Overall confidence in the pooled results was addressed using the Grades of Recommendation, Assessment, Development and Evaluation (GRADE) approach [5]. Confidence ratings are important because they reflect variations in the design of the primary studies, the risk of bias within and across the primary studies, the degree of imprecision in the pooled results, inconsistency, and indirectness. The GRADE approach has been adopted by more than 70 major health research organizations because it is transparent, structured, and comprehensive enough to guide treatment recommendations. The quality of the evidence for most comparisons in this meta-analysis was low or very low, which indicates that our confidence in the pooled effect estimates is actually limited and that the pooled estimates might differ substantially from reality. In comparison to sliding hip screws, the potential advantages of nailing include a shorter and more rigid moment arm and the contention that insertion is less invasive. However, nails cost between USD 700 and USD 1700 more per implant than sliding hip screws [12] and patient-important functional outcomes across most fracture patterns are similar in the current literature [10]. A recent economic evaluation found that intramedullary nail fixation was routinely cost-effective only for A3 fractures while sliding hip screw fixation was favored for all A1 fractures and most A2 fractures [12], but these conclusions were highly sensitive to the fixation failure rates. Given that older nails were associated with more reoperations and intra and postoperative fractures, and that modern nails and increased clinical experience may have solved these issues [2], further research comparing modern nails against sliding hip screws is likely to be of substantial value. At least one adequately powered multicenter randomized trial is currently registered and underway (NCT01380444), but additional trials and other study designs will also be needed to evaluate varying fracture patterns across different patient populations.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,005
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Revue systématique · Signal consensuel: Revue systématique
GenreSignal candidat: Synthèse · Signal consensuel: Synthèse
Score de désaccord entre enseignants0,021
Score d'incertitude au seuil0,070

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0010,005
Méta-épidémiologie (sens strict)0,0020,000
Méta-épidémiologie (sens large)0,0040,003
Bibliométrie0,0040,004
Études des sciences et des technologies0,0000,000
Communication savante0,0010,001
Science ouverte0,0010,001
Intégrité de la recherche0,0010,001
Charge utile insuffisante (le modèle a refusé de juger)0,0210,002

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,189
Tête enseignante GPT0,567
Écart entre enseignants0,377 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeRevue systématique
Domainenon disponible
GenreSynthèse

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations24
Publié2015
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueClinical Orthopaedics and Related ResearchMême sujetHip and Femur FracturesTravaux en français237 207