MétaCan
Menu
Retour à la cohorte
Enregistrement W2097897456 · doi:10.1373/clinchem.2013.220467

A Mother and Newborn with Brown Blood

2015· article· en· W2097897456 sur OpenAlexaff
Mathew P. Estey, Gwen Clarke, Winnie Sia, E. J. Toor, Trefor Higgins

Notice bibliographique

RevueClinical Chemistry · 2015
Typearticle
Langueen
DomaineMedicine
ThématiqueMethemoglobinemia and Tumor Lysis Syndrome
Établissements canadiensRoyal Alexandra HospitalUniversity of Alberta
Organismes subventionnairesnon disponible
Mots-clésMedicine

Résumé

récupéré en direct d'OpenAlex

A 33-year-old woman of Indian origin presented for prenatal care at term. An ultrasound report from earlier in her pregnancy indicated complete placenta previa and placenta increta, which were confirmed by repeat ultrasound. She was admitted to the hospital for monitoring and delivery planning. On admission, brown vaginal spotting was noted on the patient's pad. Her nail beds and fingers were cyanotic, and a finger prick blood sample was rusty brown in appearance. Oxygen saturation by pulse oximetry on room air was 45% despite her appearing clinically well. She was otherwise asymptomatic. The patient's husband remarked that her family has “brown blood, not red,” noting that the patient's father, paternal grandfather, and sister also have brown blood but no clinical problems. Her 3-year-old daughter had a similar cyanotic appearance but was otherwise asymptomatic. Repeat oxygen saturation measurements by pulse oximetry consistently gave results between 40%–60%, and arterial blood Po2 was 95 mmHg. Methemoglobin measurement was attempted, but the cooximeter indicated “?Oximetry measuring error.” This was also confirmed by repeated measurements. Complete blood count results were as follows: hemoglobin, 12.5 g/dL (125 g/L; reference interval, 120–160 g/L); red blood cells (RBC),6 4.19 × 1012/L (reference interval, 3.80–5.20 × 1012/L); hematocrit (HCT), 38% (0.38; reference interval, 0.36–0.46); mean corpuscular volume (MCV), 90 fL (reference interval, 80–100 fL); mean corpuscular hemoglobin (MCH), 30 pg (reference interval, 26–35 pg); mean corpuscular hemoglobin concentration (MCHC), 33.3 g/dL (333 g/L; reference interval, 310–360 g/L); red cell width distribution (RDW), 13.2% (reference interval, <15.6%); platelets (PLT), 224 × 109/L (reference interval, 140–450 × 109/L); white blood cells (WBC) 9.6 × 109/L (reference interval, 4.0–11.0 × 109/L). What are causes of cyanosis and brown blood? What additional laboratory tests could be useful in this case? What could cause both the pulse oximeter and cooximeter to give unusual results? A peripheral blood film showed mild anemia with microcytes, no significant polychromasia or poikilocytosis, and neutrophils with prominent granulation. There was no increase in reticulocyte count, and glucose-6-phosphate dehydrogenase activity was normal. The newborn child was also found to be cyanotic at birth, with brown blood similar to the mother's. Attempts to measure methemoglobin were once again unsuccessful, and oxygen saturation results by pulse oximetry were consistently very low despite normal vital signs. Complete blood count results for the infant were as follows: hemoglobin, 17.2 g/dL (172 g/L; reference interval, 135–195 g/L); RBC, 4.66 × 1012/L (reference interval, 3.90–5.50 × 1012/L); HCT, 51% (0.51; reference interval, 0.42–0.60); MCV, 110 fL (reference interval, 98–118 fL); MCH, 37 pg (reference interval, 26–35 pg); MCHC, 33.5 g/dL (335 g/L; reference interval, 330–360 g/L); RDW, 16.0% (reference interval, <15.6%); PLT, 176 × 1012/L (reference interval, 140–450 × 109/L); WBC, 12.5 × 1012/L (reference interval, 9.0–30.0 × 109/L). Cyanosis typically results from increased amounts of deoxyhemoglobin in the bloodstream. This may be due to hypoxemia, methemoglobinemia, or sulfhemoglobinemia (1). Methemalbuminemia and deposition of pigmented substances in skin may also cause cyanosis. Of these potential causes, methemoglobin and methemalbumin have absorption properties that give the blood a brown or chocolate brown color when present in sufficient amounts (1). However, methemalbumin forms as a result of excessive red blood cell destruction, which is not consistent with the patient's hematological studies. Methemoglobin is formed through the oxidation of the heme iron from Fe2+ to Fe3+. This form of hemoglobin cannot bind oxygen, and it increases the oxygen affinity of the other heme groups within the hemoglobin tetramer. Consequently, methemoglobin causes cyanosis and impairs oxygen delivery to tissues. The signs and symptoms of methemoglobinemia vary depending on the fraction of methemoglobin. Methemoglobin values of 10%–20% cause clinically obvious cyanosis and brown blood; however, the patient may be otherwise asymptomatic. Methemoglobin above 30% may cause dyspnea, nausea, and tachycardia, whereas lethargy, syncope, loss of consciousness, and coma may occur when methemoglobin reaches 55% (2). Methemoglobin above 70% is incompatible with life. Under normal circumstances, the vast majority of hemoglobin (approximately 98%) is held in the reduced state. This is achieved predominantly through reduction of methemoglobin in an NADH-dependent manner by an enzyme called methemoglobin reductase (also known as NADH-cytochrome b5 reductase). Methemoglobinemia may be due to either acquired or congenital causes. In most instances, consumption of an exogenous oxidizing agent causes oxidative stress, which overwhelms the body's capacity to hold hemoglobin in the reduced state. Both chemicals (such as aniline dyes, pesticides, and fava beans) and medications (including dapsone, nitrous oxide, and quinine-based antimalaria drugs) can cause acquired methemoglobinemia (3). Congenital methemoglobinemia may be due to defects in methemoglobin reductase. Alternatively, certain hemoglobin mutations shift the equilibrium toward the oxidized state, thereby also causing congenital methemoglobinemia. These hemoglobin variants are referred to as M (met) hemoglobins (Hb M). Patients with congenital methemoglobinemia typically have methemoglobin in the range of 15%–20%, whereas much higher amounts may occur in acquired methemoglobinemia. Given the positive family history of brown blood, a congenital cause of methemoglobinemia was suspected. The patient's methemoglobin reductase activity was found to be within the reference interval, ruling out methemoglobin reductase deficiency. Consequently, the presence of a hemoglobin variant was investigated. Hemoglobin analysis by HPLC revealed an abnormal peak with a retention time of 4.72 min, comprising 17.3% of the total hemoglobin (Fig. 1A). A small shoulder peak with a slightly longer retention time than the parent peak, which is characteristic of α-chain hemoglobin variants, was noted. Interestingly, the chromatography profile did not resemble that of any Hb M found in 2 independent databases of hemoglobin variants [Bio-Rad library of variants and Variant Haemoglobins: A Guide to Identification (4)]. The best putative match according to both of these databases was Hb Q-India (Table 1). HPLC analysis of the newborn's blood also suggested the presence of an α chain hemoglobin variant (data not shown). The presence of cyanosis and brown blood in the neonate further supports an α chain variant, since a β chain mutation would present several months later due to low β chain expression at birth. (A), HPLC profile using the Bio-Rad Variant II β-thalassemia Short Program. The positions of Hb A, Hb A2, and the variant are indicated. The arrow points to a small shoulder peak, which is characteristic of α chain hemoglobin variants. (B and C), Electrophoresis at alkaline (B) and acid (C) pH using the Sebia Hydrasys system. The positions of hemoglobin C, S, A, F, and I are indicated. The asterisk denotes the patient's sample. Chromatographic and electrophoretic properties of the patient's hemoglobin variant and those expected for Hb Q-India. Bain et al. (4). Chromatographic and electrophoretic properties of the patient's hemoglobin variant and those expected for Hb Q-India. Bain et al. (4). As recommended by the British Journal of Hematology guidelines for screening and diagnosing hemoglobin variants (5), an alternate method for hemoglobin identification based on a different analytical principle was performed. Electrophoresis at alkaline pH revealed bands in the A and S positions (Fig. 1B), which is consistent with Hb Q-India trait (4). However, electrophoresis at acid pH also revealed bands in the A and S positions (Fig. 1C), whereas a single band in the A position would be expected for the Hb Q-India trait (4). An Indian colleague was consulted and felt that the available data (Table 1) were most consistent with the presence of Hb Q-India. She noted that “brown blood disease” is frequently found in certain parts of India and is associated with the presence of Hb Q-India. Since there is no literature demonstrating a causative link between Hb Q-India and methemoglobinemia, gene sequencing was performed to definitively identify the hemoglobin variant. The results indicated heterozygosity for Hb M-Boston (HBA2 c.175C>T), a rare α chain variant first described in the late 1950s and early 1960s (6, 7). Whereas the chromatographic properties of Hb M-Boston on the BioRad Variant Classic have been described previously (8), characterization of its mobility relative to other hemoglobin variants using modern electrophoresis systems is lacking. The single His58Tyr mutation in Hb M-Boston results in a conformational change in the α subunit that explains many of the clinical findings observed in this case. First, the conformational change stabilizes the hemoglobin tetramer in the deoxy state (9), thus reducing the oxygen affinity and causing cyanosis. Second, the conformational change renders Hb M-Boston resistant to reduction by methemoglobin reductase (10). This causes methemoglobinemia, which both contributes to the cyanosis and accounts for the presence of brown blood. Finally, the conformational change also alters the absorption spectrum of Hb M-Boston relative to both Hb A and methemoglobin A (11). Because measurements of oxygen saturation and methemoglobin are based on the absorbance of Hb A at characteristic wavelengths, the presence of a hemoglobin variant with different absorption properties will interfere with these measurements (11). Thus, the presence of Hb M-Boston also explains the severely underestimated oxygen saturation results and the inability to measure methemoglobin. Although this is also the case for other M hemoglobins, it is not an issue in acquired methemoglobinemia or methemoglobin reductase deficiency (since methemoglobin A is produced in these instances). Patients with methemoglobinemia may present with cyanosis and brown blood. Methemoglobinemia may be acquired (drug or chemically induced) or inherited (methemoglobin reductase deficiency or Hb M). The cause of methemoglobinemia may be assessed by measuring methemoglobin and methemoglobin reductase activity, and by performing a hemoglobinopathy investigation (acquiring a family, medication, and chemical exposure history are also critical). HPLC and gel electrophoresis (at both acid and alkaline pH) play an important role in identifying hemoglobin variants. However, different variants may have similar profiles using some or all of these techniques. Gene sequencing provides definitive identification, and is especially useful in identifying rare variants. Oxygen saturation measurement by pulse oximetry and methemoglobin measurement by cooximetry may be unreliable or unobtainable in the presence of Hb M. This case confirms that definitive identification of a hemoglobin variant is not always possible using HPLC and electrophoresis, even when both techniques are used in parallel. Indeed, with the use of these techniques alone, Hb M-Boston could easily be mistaken for Hb Q-India. To our knowledge, this is the first description of Hb M-Boston in a patient of Indian ethnicity. Given the lack of evidence demonstrating a causative link between Hb Q-India and methemoglobinemia, it is tempting to speculate that Hb M-Boston may actually be more prevalent in Indian populations, yet is being misidentified as Hb Q-India. red blood cells hematocrit mean corpuscular volume mean corpuscular hemoglobin mean corpuscular hemoglobin concentration red cell width distribution platelets white blood cells met hemoglobin M. Sequencing was performed at the Hamilton Hematology and Genetics Laboratory, and methemoglobin reductase activity was assessed at Mayo Medical Laboratories.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,003
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Étude de cas · Signal consensuel: Étude de cas
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,006
Score d'incertitude au seuil0,012

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0000,003
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0010,001
Études des sciences et des technologies0,0030,001
Communication savante0,0010,001
Science ouverte0,0010,001
Intégrité de la recherche0,0010,002
Charge utile insuffisante (le modèle a refusé de juger)0,0030,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,060
Tête enseignante GPT0,334
Écart entre enseignants0,275 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeÉtude de cas
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations7
Publié2015
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueClinical ChemistryMême sujetMethemoglobinemia and Tumor Lysis SyndromeTravaux en français237 207