MétaCan
Menu
Retour à la cohorte
Enregistrement W2122403266 · doi:10.1016/j.jvsc.2015.07.004

Management of acute limb ischemia after glue embolization of endoleak following endovascular abdominal aortic aneurysm repair

2015· article· en· W2122403266 sur OpenAlexaff
Maged Metias, Ahmed Kayssi, Thomas F. Lindsay, Dheeraj K. Rajan

Notice bibliographique

RevueJournal of Vascular Surgery Cases · 2015
Typearticle
Langueen
DomaineMedicine
ThématiqueAortic aneurysm repair treatments
Établissements canadiensUniversity of Toronto
Organismes subventionnairesnon disponible
Mots-clésMedicineEmbolizationSurgeryAneurysmAbdominal aortic aneurysmEmbolectomyCyanoacrylateIschemiaEndovascular aneurysm repairAortic aneurysmRadiologyCardiology

Résumé

récupéré en direct d'OpenAlex

We describe the case of a 73-year-old woman who developed a type II endoleak and subsequent aneurysm sac expansion following endovascular abdominal aortic aneurysm repair. The endoleak was treated with a translumbar direct sac puncture and injection with n-butyl-2-cyanoacrylate. During the injection procedure, glue embolized distally, lodging into the right popliteal, proximal anterior tibial, and tibioperoneal arteries, causing acute limb ischemia that led to an emergency embolectomy. The patient recovered well, and the postoperative course was unremarkable. Acute limb ischemia secondary to glue embolization during endoleak management is rare, with potentially catastrophic complications that require urgent operative repair. We describe the case of a 73-year-old woman who developed a type II endoleak and subsequent aneurysm sac expansion following endovascular abdominal aortic aneurysm repair. The endoleak was treated with a translumbar direct sac puncture and injection with n-butyl-2-cyanoacrylate. During the injection procedure, glue embolized distally, lodging into the right popliteal, proximal anterior tibial, and tibioperoneal arteries, causing acute limb ischemia that led to an emergency embolectomy. The patient recovered well, and the postoperative course was unremarkable. Acute limb ischemia secondary to glue embolization during endoleak management is rare, with potentially catastrophic complications that require urgent operative repair. Endoleaks after endovascular abdominal aortic aneurysm repair (EVAR) often resolve spontaneously, but treatment is recommended when there is evidence of aneurysm sac expansion of >0.5 cm. Options for repair include vessel coiling and embolization with a liquid embolic adhesive such as n-butyl-2-cyanoacrylate (n-BCA).1Day C.P. Buckenham T.M. Laing A.D. Embolization of proximal type 1 endoleak using N-butyl 2-cyanoacrylate after endovascular repair of the thoracic aorta: two case reports.J Vasc Interv Radiol. 2011; 22: 105-107Abstract Full Text Full Text PDF PubMed Scopus (9) Google Scholar, 2Maldonado T.S. Rosen R.J. Rockman C.B. Adelman M.A. Bajakian D. Jacobowitz G.R. et al.Initial successful management of type I endoleak after endovascular aortic aneurysm repair with n-butyl cyanoacrylate adhesive.J Vasc Surg. 2003; 38: 664-670Abstract Full Text Full Text PDF PubMed Scopus (93) Google Scholar In this report, we present a case of endoleak treatment with n-BCA adhesive in which the glue entered the circulation, leading to embolization to the peripheral extremities and causing acute limb ischemia that required urgent operative repair. The patient has consented to the publication of this case report. A 73-year-old woman with a 50 pack-year smoking history was referred for management of an asymptomatic, infrarenal abdominal aortic aneurysm measuring 4.9 cm and right and left common iliac artery aneurysms measuring 4.1 × 3.7 cm and 2.2 × 2.4 cm, respectively. The patient subsequently underwent an endovascular repair with an Anaconda abdominal aortic aneurysm stent graft system (Vascutek, Scotland, UK). A small type Ia endoleak was noted intraoperatively, and an attempt to seal the proximal stent with a balloon was unsuccessful. A postoperative computed tomography (CT) scan performed the following day confirmed the persistence of the endoleak. A four-phase CT scan protocol was used that had a noncontrast phase as well as active imaging arterial to venous phases, which allowed accurate determination of the type and location of the endoleak. The size of the endoleak was small, and the decision was made to discharge the patient home and to observe the endoleak with serial imaging. She was seen in the clinic 4 weeks after discharge from the hospital, and a Doppler study did not show any evidence of a persistent endoleak or aneurysmal sac enlargement. A follow-up CT scan performed 6 months postoperatively demonstrated resolution of the type Ia endoleak. However, a new type II endoleak was noted to originate from the lumbar arteries with evidence of aneurysmal sac expansion (4.1 × 3.7 cm to 4.3 × 5.4 cm; Fig 1). The patient was asymptomatic and wanted to be observed with serial imaging to monitor the sac growth rather than undergo treatment. Follow-up CT scans at 12 and 18 months showed minimal sac growth, after which the patient was willing to undergo an intervention. The patient subsequently underwent a translumbar direct sac puncture and embolization of the endoleak 19 months after EVAR was performed. The aneurysm sac was accessed using an 18-gauge trocar needle under fluoroscopic guidance, and a 2.8 F Progreat microcatheter (Terumo, Somerset, NJ) was inserted. Injection of the sac with contrast material demonstrated no type I endoleak, but the patient had evidence of a type II endoleak with filling of an enlarged lumbar artery (Fig 2). We filled the lumbar arteries and the vessels feeding the aneurysm sac with contrast material and again observed no evidence of a type I endoleak. Catheterization of the lumbar arteries was attempted but not possible from the sac. The volume of contrast material required to completely fill the sac during fluoroscopy was 5 mL, and as such, 5 mL of an n-BCA and lipiodol mixture in a 1:4 ratio was injected into the aneurysm sac under fluoroscopic guidance.Fig 2Injection of sac demonstrates type II endoleak with filling lumbar artery (arrow). No evidence of type Ia endoleak.View Large Image Figure ViewerDownload (PPT) During injection of the final 0.5 mL of the adhesive, there was a sudden cephalad movement of the glue mixture around the proximal sealing stent in the neck into the perirenal aorta. This traveled through the stent graft lumen and into the right limb, down to the right popliteal artery, and lodged into the proximal anterior tibial artery, tibioperoneal trunk, and distal popliteal artery, casting the vessels (Fig 3, A-C). Intravenous heparin (6000 units) was administered, and the patient was transferred to the operating room for an emergent embolectomy. In the operating room, the popliteal artery was exposed through a standard medial calf incision. The popliteal artery and the anterior tibial artery and the tibioperoneal trunk were controlled. A longitudinal arteriotomy was made in the mid-popliteal artery, and the embolized glue was successfully extracted with a Howarth elevator (Fig 3, D). Selective embolectomies of the anterior tibial artery, tibioperoneal trunk, and distal superficial femoral artery were performed. Excellent inflow and copious back-bleeding from the anterior tibial and posterior tibial trunk was obtained. The artery was then repaired with a bovine pericardial patch and a running 4-0 Prolene suture. At the end of the procedure, the patient had palpable pulses and a well-perfused foot. No fasciotomies were necessary. The patient's postoperative course was uncomplicated, and she was discharged home in stable condition. During an outpatient clinic follow-up visit approximately 1.5 months after discharge, the patient had no complaints and was ambulating normally. Her ankle pressures normalized. A follow-up CT scan demonstrated resolution of the endoleak. The prevalence of type I and type II endoleaks has been reported to be as high as 10% to 25%.3van Marrewijk C. Buth J. Harris P.L. Norgren L. Nevelsteen A. Wyatt M.G. Significance of endoleaks after endovascular repair of abdominal aortic aneurysms: the EUROSTAR experience.J Vasc Surg. 2002; 35: 461-473Abstract Full Text Full Text PDF PubMed Scopus (434) Google Scholar, 4Veith F.J. Baum R.A. Ohki T. Amor M. Adiseshiah M. Blankensteijn J.D. et al.Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference.J Vasc Surg. 2002; 35: 1029-1035Abstract Full Text Full Text PDF PubMed Scopus (552) Google Scholar In our patient, the presence of a short neck on the aneurysm as well as sharp angulation (>60 degrees) may have increased the risk of a type I endoleak.5Rosen R.J. Green R.M. Endoleak management following endovascular aneurysm repair.J Vasc Interv Radiol. 2008; 19: S37-S43Abstract Full Text Full Text PDF PubMed Scopus (64) Google Scholar Endoleak therapy is recommended if sac growth exceeds 0.5 cm because of the risk of aneurysmal sac rupture.6Buth J. Harris P.L. van Marrewijk C. Fransen G. The significance and management of different types of endoleaks.Semin Vasc Surg. 2003; 16: 95-102Abstract Full Text Full Text PDF PubMed Scopus (106) Google Scholar, 7Maldonado T.S. Gagne P.J. Controversies in the management of type II “branch” endoleaks following endovascular abdominal aortic aneurysm repair.Vasc Endovascular Surg. 2003; 37: 1-12Crossref PubMed Scopus (37) Google Scholar, 8Tuerff S.N. Rockman C.B. Lamparello P.J. Adelman M.A. Jacobowitz G.R. Gagne P.J. et al.Are type II (branch vessel) endoleaks really benign?.Ann Vasc Surg. 2002; 16: 50-54Abstract Full Text PDF PubMed Scopus (43) Google Scholar Type Ia endoleaks are frequently managed through endovascular techniques to seal the proximal end in one of three ways: reinflation of a balloon at the proximal rim of the stent, endograft extensions at the proximal landing zone, or placement of a balloon-expandable bare stent at the site of attachment to provide greater radial forces for a better seal.9Choi S.Y. Lee do Y. Lee K.H. Ko Y.G. Choi D. Shim W.H. et al.Treatment of type I endoleaks after endovascular aneurysm repair of infrarenal abdominal aortic aneurysm: usefulness of N-butyl cyanoacrylate embolization in cases of failed secondary endovascular intervention.J Vasc Interv Radiol. 2011; 22: 155-162Abstract Full Text Full Text PDF PubMed Scopus (25) Google Scholar, 10Ricotta 2nd, J.J. Endoleak management and postoperative surveillance following endovascular repair of thoracic aortic aneurysms.J Vasc Surg. 2010; 52: 91S-99SAbstract Full Text Full Text PDF PubMed Scopus (51) Google Scholar In this case, despite the relatively small volume of n-BCA that was injected slowly and carefully, the glue embolization was thought to have occurred by overpressurizing the sac in an attempt to fill the lumbar artery. The glue mixture subsequently “squirted” up along a tract that was possibly the original area of type I endoleak. Another possibility is that the nitinol sealing ring with the Anaconda device became temporarily deformed under pressure, allowing glue to reflux upward. n-BCA has been successful in the management of endoleaks, with a 6-month success rate as high as 92.3%.2Maldonado T.S. Rosen R.J. Rockman C.B. Adelman M.A. Bajakian D. Jacobowitz G.R. et al.Initial successful management of type I endoleak after endovascular aortic aneurysm repair with n-butyl cyanoacrylate adhesive.J Vasc Surg. 2003; 38: 664-670Abstract Full Text Full Text PDF PubMed Scopus (93) Google Scholar, 9Choi S.Y. Lee do Y. Lee K.H. Ko Y.G. Choi D. Shim W.H. et al.Treatment of type I endoleaks after endovascular aneurysm repair of infrarenal abdominal aortic aneurysm: usefulness of N-butyl cyanoacrylate embolization in cases of failed secondary endovascular intervention.J Vasc Interv Radiol. 2011; 22: 155-162Abstract Full Text Full Text PDF PubMed Scopus (25) Google Scholar Whereas coil embolization of collateral feeding vessels is an equally valid treatment modality for this vexing problem, in our experience it takes significantly longer procedural and fluoroscopy time compared with n-BCA injection through direct sac puncture, and we have had similar success rates with both modalities. Furthermore, when it is injected carefully, n-BCA better fills out the sac and exerts a molding effect that blocks the sac's feeding vessels.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,224
Score d'incertitude au seuil0,965

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,002
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,020
Tête enseignante GPT0,274
Écart entre enseignants0,253 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations1
Publié2015
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueJournal of Vascular Surgery CasesMême sujetAortic aneurysm repair treatmentsTravaux en français237 207