MétaCan
Menu
Back to cohort
Record W2122403266 · doi:10.1016/j.jvsc.2015.07.004

Management of acute limb ischemia after glue embolization of endoleak following endovascular abdominal aortic aneurysm repair

2015· article· en· W2122403266 on OpenAlexaff
Maged Metias, Ahmed Kayssi, Thomas F. Lindsay, Dheeraj K. Rajan

Bibliographic record

VenueJournal of Vascular Surgery Cases · 2015
Typearticle
Languageen
FieldMedicine
TopicAortic aneurysm repair treatments
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsMedicineEmbolizationSurgeryAneurysmAbdominal aortic aneurysmEmbolectomyCyanoacrylateIschemiaEndovascular aneurysm repairAortic aneurysmRadiologyCardiology

Abstract

fetched live from OpenAlex

We describe the case of a 73-year-old woman who developed a type II endoleak and subsequent aneurysm sac expansion following endovascular abdominal aortic aneurysm repair. The endoleak was treated with a translumbar direct sac puncture and injection with n-butyl-2-cyanoacrylate. During the injection procedure, glue embolized distally, lodging into the right popliteal, proximal anterior tibial, and tibioperoneal arteries, causing acute limb ischemia that led to an emergency embolectomy. The patient recovered well, and the postoperative course was unremarkable. Acute limb ischemia secondary to glue embolization during endoleak management is rare, with potentially catastrophic complications that require urgent operative repair. We describe the case of a 73-year-old woman who developed a type II endoleak and subsequent aneurysm sac expansion following endovascular abdominal aortic aneurysm repair. The endoleak was treated with a translumbar direct sac puncture and injection with n-butyl-2-cyanoacrylate. During the injection procedure, glue embolized distally, lodging into the right popliteal, proximal anterior tibial, and tibioperoneal arteries, causing acute limb ischemia that led to an emergency embolectomy. The patient recovered well, and the postoperative course was unremarkable. Acute limb ischemia secondary to glue embolization during endoleak management is rare, with potentially catastrophic complications that require urgent operative repair. Endoleaks after endovascular abdominal aortic aneurysm repair (EVAR) often resolve spontaneously, but treatment is recommended when there is evidence of aneurysm sac expansion of >0.5 cm. Options for repair include vessel coiling and embolization with a liquid embolic adhesive such as n-butyl-2-cyanoacrylate (n-BCA).1Day C.P. Buckenham T.M. Laing A.D. Embolization of proximal type 1 endoleak using N-butyl 2-cyanoacrylate after endovascular repair of the thoracic aorta: two case reports.J Vasc Interv Radiol. 2011; 22: 105-107Abstract Full Text Full Text PDF PubMed Scopus (9) Google Scholar, 2Maldonado T.S. Rosen R.J. Rockman C.B. Adelman M.A. Bajakian D. Jacobowitz G.R. et al.Initial successful management of type I endoleak after endovascular aortic aneurysm repair with n-butyl cyanoacrylate adhesive.J Vasc Surg. 2003; 38: 664-670Abstract Full Text Full Text PDF PubMed Scopus (93) Google Scholar In this report, we present a case of endoleak treatment with n-BCA adhesive in which the glue entered the circulation, leading to embolization to the peripheral extremities and causing acute limb ischemia that required urgent operative repair. The patient has consented to the publication of this case report. A 73-year-old woman with a 50 pack-year smoking history was referred for management of an asymptomatic, infrarenal abdominal aortic aneurysm measuring 4.9 cm and right and left common iliac artery aneurysms measuring 4.1 × 3.7 cm and 2.2 × 2.4 cm, respectively. The patient subsequently underwent an endovascular repair with an Anaconda abdominal aortic aneurysm stent graft system (Vascutek, Scotland, UK). A small type Ia endoleak was noted intraoperatively, and an attempt to seal the proximal stent with a balloon was unsuccessful. A postoperative computed tomography (CT) scan performed the following day confirmed the persistence of the endoleak. A four-phase CT scan protocol was used that had a noncontrast phase as well as active imaging arterial to venous phases, which allowed accurate determination of the type and location of the endoleak. The size of the endoleak was small, and the decision was made to discharge the patient home and to observe the endoleak with serial imaging. She was seen in the clinic 4 weeks after discharge from the hospital, and a Doppler study did not show any evidence of a persistent endoleak or aneurysmal sac enlargement. A follow-up CT scan performed 6 months postoperatively demonstrated resolution of the type Ia endoleak. However, a new type II endoleak was noted to originate from the lumbar arteries with evidence of aneurysmal sac expansion (4.1 × 3.7 cm to 4.3 × 5.4 cm; Fig 1). The patient was asymptomatic and wanted to be observed with serial imaging to monitor the sac growth rather than undergo treatment. Follow-up CT scans at 12 and 18 months showed minimal sac growth, after which the patient was willing to undergo an intervention. The patient subsequently underwent a translumbar direct sac puncture and embolization of the endoleak 19 months after EVAR was performed. The aneurysm sac was accessed using an 18-gauge trocar needle under fluoroscopic guidance, and a 2.8 F Progreat microcatheter (Terumo, Somerset, NJ) was inserted. Injection of the sac with contrast material demonstrated no type I endoleak, but the patient had evidence of a type II endoleak with filling of an enlarged lumbar artery (Fig 2). We filled the lumbar arteries and the vessels feeding the aneurysm sac with contrast material and again observed no evidence of a type I endoleak. Catheterization of the lumbar arteries was attempted but not possible from the sac. The volume of contrast material required to completely fill the sac during fluoroscopy was 5 mL, and as such, 5 mL of an n-BCA and lipiodol mixture in a 1:4 ratio was injected into the aneurysm sac under fluoroscopic guidance.Fig 2Injection of sac demonstrates type II endoleak with filling lumbar artery (arrow). No evidence of type Ia endoleak.View Large Image Figure ViewerDownload (PPT) During injection of the final 0.5 mL of the adhesive, there was a sudden cephalad movement of the glue mixture around the proximal sealing stent in the neck into the perirenal aorta. This traveled through the stent graft lumen and into the right limb, down to the right popliteal artery, and lodged into the proximal anterior tibial artery, tibioperoneal trunk, and distal popliteal artery, casting the vessels (Fig 3, A-C). Intravenous heparin (6000 units) was administered, and the patient was transferred to the operating room for an emergent embolectomy. In the operating room, the popliteal artery was exposed through a standard medial calf incision. The popliteal artery and the anterior tibial artery and the tibioperoneal trunk were controlled. A longitudinal arteriotomy was made in the mid-popliteal artery, and the embolized glue was successfully extracted with a Howarth elevator (Fig 3, D). Selective embolectomies of the anterior tibial artery, tibioperoneal trunk, and distal superficial femoral artery were performed. Excellent inflow and copious back-bleeding from the anterior tibial and posterior tibial trunk was obtained. The artery was then repaired with a bovine pericardial patch and a running 4-0 Prolene suture. At the end of the procedure, the patient had palpable pulses and a well-perfused foot. No fasciotomies were necessary. The patient's postoperative course was uncomplicated, and she was discharged home in stable condition. During an outpatient clinic follow-up visit approximately 1.5 months after discharge, the patient had no complaints and was ambulating normally. Her ankle pressures normalized. A follow-up CT scan demonstrated resolution of the endoleak. The prevalence of type I and type II endoleaks has been reported to be as high as 10% to 25%.3van Marrewijk C. Buth J. Harris P.L. Norgren L. Nevelsteen A. Wyatt M.G. Significance of endoleaks after endovascular repair of abdominal aortic aneurysms: the EUROSTAR experience.J Vasc Surg. 2002; 35: 461-473Abstract Full Text Full Text PDF PubMed Scopus (434) Google Scholar, 4Veith F.J. Baum R.A. Ohki T. Amor M. Adiseshiah M. Blankensteijn J.D. et al.Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference.J Vasc Surg. 2002; 35: 1029-1035Abstract Full Text Full Text PDF PubMed Scopus (552) Google Scholar In our patient, the presence of a short neck on the aneurysm as well as sharp angulation (>60 degrees) may have increased the risk of a type I endoleak.5Rosen R.J. Green R.M. Endoleak management following endovascular aneurysm repair.J Vasc Interv Radiol. 2008; 19: S37-S43Abstract Full Text Full Text PDF PubMed Scopus (64) Google Scholar Endoleak therapy is recommended if sac growth exceeds 0.5 cm because of the risk of aneurysmal sac rupture.6Buth J. Harris P.L. van Marrewijk C. Fransen G. The significance and management of different types of endoleaks.Semin Vasc Surg. 2003; 16: 95-102Abstract Full Text Full Text PDF PubMed Scopus (106) Google Scholar, 7Maldonado T.S. Gagne P.J. Controversies in the management of type II “branch” endoleaks following endovascular abdominal aortic aneurysm repair.Vasc Endovascular Surg. 2003; 37: 1-12Crossref PubMed Scopus (37) Google Scholar, 8Tuerff S.N. Rockman C.B. Lamparello P.J. Adelman M.A. Jacobowitz G.R. Gagne P.J. et al.Are type II (branch vessel) endoleaks really benign?.Ann Vasc Surg. 2002; 16: 50-54Abstract Full Text PDF PubMed Scopus (43) Google Scholar Type Ia endoleaks are frequently managed through endovascular techniques to seal the proximal end in one of three ways: reinflation of a balloon at the proximal rim of the stent, endograft extensions at the proximal landing zone, or placement of a balloon-expandable bare stent at the site of attachment to provide greater radial forces for a better seal.9Choi S.Y. Lee do Y. Lee K.H. Ko Y.G. Choi D. Shim W.H. et al.Treatment of type I endoleaks after endovascular aneurysm repair of infrarenal abdominal aortic aneurysm: usefulness of N-butyl cyanoacrylate embolization in cases of failed secondary endovascular intervention.J Vasc Interv Radiol. 2011; 22: 155-162Abstract Full Text Full Text PDF PubMed Scopus (25) Google Scholar, 10Ricotta 2nd, J.J. Endoleak management and postoperative surveillance following endovascular repair of thoracic aortic aneurysms.J Vasc Surg. 2010; 52: 91S-99SAbstract Full Text Full Text PDF PubMed Scopus (51) Google Scholar In this case, despite the relatively small volume of n-BCA that was injected slowly and carefully, the glue embolization was thought to have occurred by overpressurizing the sac in an attempt to fill the lumbar artery. The glue mixture subsequently “squirted” up along a tract that was possibly the original area of type I endoleak. Another possibility is that the nitinol sealing ring with the Anaconda device became temporarily deformed under pressure, allowing glue to reflux upward. n-BCA has been successful in the management of endoleaks, with a 6-month success rate as high as 92.3%.2Maldonado T.S. Rosen R.J. Rockman C.B. Adelman M.A. Bajakian D. Jacobowitz G.R. et al.Initial successful management of type I endoleak after endovascular aortic aneurysm repair with n-butyl cyanoacrylate adhesive.J Vasc Surg. 2003; 38: 664-670Abstract Full Text Full Text PDF PubMed Scopus (93) Google Scholar, 9Choi S.Y. Lee do Y. Lee K.H. Ko Y.G. Choi D. Shim W.H. et al.Treatment of type I endoleaks after endovascular aneurysm repair of infrarenal abdominal aortic aneurysm: usefulness of N-butyl cyanoacrylate embolization in cases of failed secondary endovascular intervention.J Vasc Interv Radiol. 2011; 22: 155-162Abstract Full Text Full Text PDF PubMed Scopus (25) Google Scholar Whereas coil embolization of collateral feeding vessels is an equally valid treatment modality for this vexing problem, in our experience it takes significantly longer procedural and fluoroscopy time compared with n-BCA injection through direct sac puncture, and we have had similar success rates with both modalities. Furthermore, when it is injected carefully, n-BCA better fills out the sac and exerts a molding effect that blocks the sac's feeding vessels.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.224
Threshold uncertainty score0.965

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.274
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Vascular Surgery CasesSame topicAortic aneurysm repair treatmentsFrench-language works237,207