Exercise hemodynamic and neurohormone responses as sensitive biomarkers for diltiazem in rats.
Notice bibliographique
Résumé
PURPOSE: To investigate the potential of exercise hemodyanamic and neurohormone variables as sensitive biomarkers for pre-clinical evaluation of diltiazem (DTZ). METHODS: Sprague Dawley (SD) rats were randomly divided into 3 groups (n = 6 - 8 each), and each group received DTZ 10 mg/kg twice daily for 5 doses or saline followed by a treadmill exercise protocol for 7 min with speed set at 7 m/min at 3 % grade. The 3rd group received saline but no exercise. RESULTS: Exercise increased SBP from 108 +/- 2 to 131 +/- 3 mmHg, and HR from 437 +/- 6 to 503 +/- 6 bpm, and plasma epinephrine concentrations from 2.0 +/- 0.6 to 5.8 +/- 1.7 ng/mL in control rats (p < 0.05 for all variables), but had no significant effect on DBP (81 +/- 5 vs 87 +/- 6 mmHg) and plasma norepinephrine concentrations (1.5 +/- 0.2 vs 3.9 +/- 0.4 ng/mL). The hemodynamic responses to exercise were significantly attenuated by DTZ (p < 0.05), but the effect on neurohormone response was minimal (p > 0.05). CONCLUSION: Exercise hemodynamic and neurohormone responses are sensitive biomarkers which could be used for safety and efficacy evaluation of DTZ and perhaps also other calcium antagonists in pre-clinical animal models.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».