Development of a humidity microsensor with thermal reset
Notice bibliographique
Résumé
The present project is aimed at developing a capacitive humidity microsensor to measure humidity profiles inside the human respiratory tract. The ultimate goal of the project is to design the sensor with minimum size and with maximum sensitivity providing minimum response time. The sensor will allow determination of humidity variation in different generations of the human lung during a breath. The design process involves an appropriate simulation of the sensor to investigate the influence of several parameters on its sensitivity, and to develop a microheater that would be used to thermally reset the sensor. This sensor consists of interdigitated electrodes formed as a capacitor using aluminum as conductor and polyimide as dielectric built on a silicon substrate. For the thermal resetting, a polysilicon microheater will be built just underneath the sensor. The system should have quick absorption of moisture and ideally have a response time of less than 1 s. This specific requirement would allow for several measurements during one breath period. In order to meet these constraints a capacitive sensor was designed with a dielectric sensitive to humidity. Other parameters such as shapes of air contact surfaces, domain dimensions, properties of materials, etc. are analyzed and results are shown as well.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».