In vitro flexibility of an experimental pedicle screw and plate instrumentation system on the porcine lumbar spine
Notice bibliographique
Résumé
The positive correlation between spinal construct stiffness and fusion rate has led to the use of increasingly rigid surgical spinal instrumentation systems. Unfortunately, however, these rigid systems have also been correlated with sub-optimal fusion quality measures. To date, in vivo studies to explore these relationships have involved the use of different implants and surgical procedures to influence the biomechanical environment at the fusion site. In order to avoid these confounding variables, a novel experimental instrumentation system has been developed which is capable of independently controlling spinal construct flexibility (inverse of stiffness). In the present study, this experimental pedicle screw and plate system was subjected to rigorous pure moment flexibility testing in flexion-extension and lateral bending using an in vitro porcine lumbar spine model. Analysis of the data showed that the system provided a reproducible, stepwise-modulated spinal construct flexibility as measured by neutral zone flexibility, laxity angle and range of motion parameters. Differences in flexibility were most evident using the neutral zone parameters (neutral zone flexibility and laxity angle). This is of particular interest given that the clinical instability of a spinal segment may be related to its behaviour within the neutral zone. This information will ultimately guide the design of improved human spinal instrumentation systems.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».