The role of a gel filled tip in maintaining the frequency response of telemetry based blood pressure measurements
Notice bibliographique
Résumé
In recent years, measurement of blood pressure via telemetry in a variety of laboratory animals has become an indispensable part of cardiovascular physiology, drug development and safety pharmacology. The solution provided by Data Sciences Inc almost 20 years ago is in the form of a catheter attached to a pressure sensor and wireless link to a remote receiver. This design features a catheter made of compliant tubing and filled at the tip with a gel material. This gel was suggested to contribute to the frequency response of blood pressure telemetry system. However, the actual influence of the specialized tip on the dynamic response of the pressure sensor has not been reported. In the present experiment, we investigated the role of the specialized gel‐filled catheter tip in the frequency response of fluid filled catheters. Experiments were carried out using a custom made sinusoidal pressure generator and the data analyzed using Labview software. The experiments reveal that the bandwidth of the DSI system is ultimately limited to less than 100 Hz by the low power transmission system and not the gel tip catheter. When a high bandwidth transmission system is available, −3 dB bandwidths of 400 Hz are attainable for rat sized catheters. The results of the study suggest that the gel tip reduces the frequency response slightly when compared to a tip‐less catheters but not to the extent that the blood pressure measurements are compromised.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».