Analyse technico-économique d'un système hybride éolien-photovoltaïque en comparaison avec les systèmes photovoltaïque et éolien seuls

2011· article· fr· W2298408032 sur OpenAlexaboutno aff
Joséanne Bélanger-Gravel

Notice bibliographique

RevuePolyPublie (École Polytechnique de Montréal) · 2011
Typearticle
Languefr
DomaineEnvironmental Science
ThématiquePhotovoltaic Systems and Sustainability
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésHumanitiesPolitical sciencePhysicsPhilosophy
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

Vu la grande superficie du territoire quebecois, de nombreuses habitations sont isolees ou a une distance importante du reseau electrique, donc les couts de raccordement au reseau sont gonfles et souvent, le raccordement est tout simplement impossible. Les systemes autonomes sont donc interessants pour alimenter en electricite les habitants de ces regions. L’utilisation de generatrices carburant aux energies fossiles est la solution actuelle. Les systemes seuls, eolien ou photovoltaique, necessitent beaucoup d’accumulateurs pour pallier a l’intermittence des gisements. Les systemes hybrides autonomes avec des panneaux solaires photovoltaiques et des eoliennes sont donc une solution potentielle limitant l’intermittence des ressources. L’analyse de diverses combinaisons de systemes est realisee en situation hors reseau et connectee au reseau. L’hypothese principale de ce travail est que si un systeme photovoltaique est joint a un systeme eolien hors reseau au Quebec, cela permet de diminuer les moments sans apport d’energie, donc on diminue les possibilites d’intermittence du systeme. Ainsi, la quantite d’accumulateurs necessaires peut etre diminuee. Cette diminution du nombre d’accumulateurs et de la taille des systemes installes se traduit en economies pour l’ensemble du systeme. L’objectif etait de comparer des systemes hybrides eoliens-photovoltaiques avec des systemes photovoltaique ou eolien seuls pour un site hors reseau au Quebec et par rapport a d'autres sites ailleurs dans le monde. Par une comparaison, la situation actuelle (diesel et connectee au reseau) a aussi ete etudiee. Dans un premier temps, les systemes seuls sont etudies. L’analyse des differentes combinaisons de systemes hybrides hors reseau et connectee au reseau est effectuee. L’originalite du projet provient dans l’addition d’un systeme photovoltaique a un systeme eolien dans un contexte quebecois et hors reseau. Globalement, les systemes seuls, eoliens ou photovoltaiques, sont une option moins viable que l’option des systemes combines utilisant ces deux energies. En general, pour le cas des systemes autonomes, il est economiquement rentable d’ajouter des eoliennes aux systemes avec generatrice diesel. Si les couts des equipements ou du diesel evoluent, l’ajout de panneaux solaires a ces systemes sera justifie. Quand les couts d’electricite auront legerement augmentes et que les couts de rachat de l’electricite par le reseau seront interessants, l’ajout de panneaux solaires, d’eoliennes et de generatrices diesel au systeme sera rentable pour le particulier dans le cas de systemes connectes au reseau. ---------- Given Quebec’s vastness, numerous homes are located in remote areas or considerably far away from the electric grid. Tying these homes to the grid is often very expensive or even impossible. Stand-alone systems are thus prime candidates to provide the energy requirements for the inhabitants of isolated locations. Currently, fossil fuel generators are the most widespread solutions. Wind- or photovoltaic-only systems require large amounts of batteries to compensate for the intermittence of resource availability. Stand-alone hybrid systems that combine both wind turbines and photovoltaic solar panels address this issue. Various combinations of both standalone and grid-connected systems are analysed. The premise of this work is that the addition of photovoltaic panels to a stand-alone wind-turbine system (in Quebec) will increase the system’s robustness to resource intermittence thereby reducing the number of required accumulators. This reduction coupled with the resulting reduction in overall system size would lead to monetary savings. The objective was to compare hybrid wind and photovoltaic systems with wind- and photovoltaic-only systems for a number of off-grid sites in Quebec and abroad. The results are compared with the current -- diesel and gridconnected – situation. This work’s contribution lies in the study of the coupling of photovoltaic systems with wind turbine systems in off-grid Quebec areas. Overall, wind- or photovoltaic-only systems are less viable that hybrid systems that use both technologies. For stand-alone systems, it is usually cost effective to add wind-turbines to diesel generator systems. If equipment or fuel costs were to increase, it would then become costeffective to also add solar panels. When the grid power price will have increased and sellback prices become worthwhile, adding solar panels, wind turbines and diesel generators to even gridtied systems will become cost-effective.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,006
score de la tête « metaresearch » (Gemma)0,001
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict), Intégrité de la recherche, Charge utile insuffisante (le modèle a refusé de juger)
Catégories consensuellesMéta-épidémiologie (sens strict)
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,607
Score d'incertitude au seuil0,999

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0060,001
Méta-épidémiologie (sens strict)0,0020,002
Méta-épidémiologie (sens large)0,0030,001
Bibliométrie0,0010,002
Études des sciences et des technologies0,0010,002
Communication savante0,0010,002
Science ouverte0,0030,002
Intégrité de la recherche0,0020,002
Charge utile insuffisante (le modèle a refusé de juger)0,0040,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,017
Tête enseignante GPT0,230
Écart entre enseignants0,212 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; les deux têtes enseignantes s’accordent sur ce qui est montré ici.

Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations1
Publié2011
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revuePolyPublie (École Polytechnique de Montréal)Même sujetPhotovoltaic Systems and SustainabilityTravaux en français237 207