300 bar<i>in situ</i>gas pressure cell for powder diffractometers
Notice bibliographique
Résumé
A new in-situ cell has been designed and constructed to simulate the temperature, pressure and chemical conditions present in deep saline aquifers.The cell has been built to study reactions at the CO 2brine-solid interfaces produced during injection of supercritical CO 2 (sc-CO 2 ) for storage and sequestration purposes.Much of the data relating to CO 2 storage relates to oil and gas wells.However, by far the largest potential reservoirs are deep saline aquifers where the chemistry has little in common with oil wells.Little experimental data exists on the behavior of various rocks and engineering materials under these conditions, particularly with injection of impure CO 2 streams, and some of the existing data give significant cause for concern.The cell has been designed for both reflection and transmission geometries so may be used both in laboratory and synchrotron environments.Although sc-CO 2 /water often reacts slowly under equilibrium, concerns have been raised about impurities such as SO 2 and H 2 S that will inevitably be present in industrial streams.These gases can react rapidly, so the slower laboratory and more rapid synchrotron measurements are highly complementary.Flow-through experiments may also be possible but haven't been specifically targeted.The cell has maximum working conditions of 300 bar pressure and 300 °C in pH3 brine conditions.These conditions are extremely demanding for any metals, sealing and window materials, and the restrictions imposed by the ASME Pressure Vessel and Boiler Code [1] and Process Piping Code [2] posed additional challenges.The materials certification requirements in the ASME code forced us into using structural grade beryllium windows as in our first generation cell [3].Beryllium is highly susceptible to chloride corrosion so a thin coating of tantalum is used to protect the windows under these conditions.Requirements of the pressure vessel certification process meant the cell was successfully tested hydrostatically to 450 bar pressure before delivery.Some of the theoretical and practical considerations for the design and construction of the cell will be described.Although the cell may be used with a laboratory diffractometer, the silver X-ray tube source and high-energy optimized PSD detector needed to gain sufficient penetration and signal are not standard components.Such a cell needs to be operated as part of an overall 'system' and is of limited use in isolation.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,002 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,004 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,003 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,021 | 0,006 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».