Frequency-adaptive current controller for grid-connected renewable energy systems
Notice bibliographique
Résumé
An adaptive proportional-resonant (APR) controller for current controller of grid-connected DC/AC systems for renewable energy applications is presented. The increase in renewable energy on the electricity grid poses stability risks to the network as the frequency and amplitude are not as tightly regulated as in previous years. The proposed APR controller is able to maintain high quality current at frequencies well beyond the IEEE1547 standard. The controller is constructed in two parts, a phase-locked loop (PLL) for synchronization and identification of the grid frequency, and a current controller based on the form of the well-known PR controller. The current controller is able to dynamically adjust to the shifting frequency of grid which ensures high quality, unity power-factor across the 59.3-60.5Hz spectrum set by IEEE1547, and beyond. The PLL implemented is an amplitude-decoupled adaptive notch filter (AANF) which provides a very fast, an accurate solution for frequency estimation as well as reference signal generation. The AANF and the APR controller are implemented digitally on an FPGA platform and verified experimentally on a 1kW DC/AC prototype.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».