Bovine Serum Albumin Adsorption on AISI 316L in Phosphate-Buffered Saline Solutions
Notice bibliographique
Résumé
Abstract Ion release and bovine serum albumin (BSA) adsorption on AISI 316L (UNS S31603) electrodes was investigated by performing cyclic voltammetry experiments and electrochemical quartz crystal microbalance (EQCM) analyses simultaneously. The quartz crystals were immersed in phosphate-buffered saline (PBS) solutions containing 2 g L-1 BSA and the potential was swept from 0.1 to -1.2 V vs. Ag/AgCl with scan rates of 50, 75, and 100 mV s-1. The results of cyclic voltammetry tests revealed one anodic and one cathodic peak. These peaks could show iron dissolution and BSA adsorption on 316L resonators. These findings were confirmed by EQCM results in which the 316L gained and lost weight loss during cathodic and anodic scans. In addition, the EQCM results indicated Faradaic dissolution of iron and adsorption of protein-water complexes on 316L. The amount of iron release and protein/water complexes adsorption were 1.49 μg cm-2 in 8.4 s and 590.6 μg cm-2 in 21.4 s, respectively.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».