Tetraethylammonium Hydroxide with Polyacrylamide As Hydroxide Conducting Polymer Electrolytes for Electrochemical Capacitors
Notice bibliographique
Résumé
Introduction Alkaline electrolytes, especially KOH, have been extensively used for energy storage devices such as batteries and electrochemical capacitors (ECs) in symmetric and asymmetric configurations [1-3]. An alkaline polymer electrolyte enables safe, thin, and flexible devices. Due to the limitation of crystallization with KOH, quaternary ammonium hydroxide based polymer electrolytes, specifically, tetraethylammonium hydroxide (TEAOH) in polyvinyl alcohol (PVA) was studied and shown to be a suitable alternative to KOH-PVA [4]. Solid AC-line filtering devices were enabled using this TEAOH-PVA polymer electrolyte [5]. However, PVA is a semi-crystalline polymer with limitations in water retention which deters the electrochemical performance of these alkaline polymer electrolytes. In this study, our objectives are to (a) develop an alkaline polymer electrolyte using TEAOH with polyacrylamide (PAM) as an alternative polymer matrix to PVA, (b) characterize the polymer electrolyte in terms of its long term ionic conductivity and material properties, and (c) fabricate solid EC devices and compare them with a liquid analogue. Experimental Aqueous TEAOH-PAM polymer electrolytes were prepared in different precursor solutions. Smooth metallic nickel (Ni) foils were used as electrodes with 1 cm2 areas. Two-electrode test vehicles were made by sandwiching TEAOH-PAM between the Ni electrodes and sealed with a chemically inert tape. Solid EC devices were made by sandwiching TEAOH-PAM between CNT-graphite electrodes on a Ni substrate with 1 cm2geometric surface areas. All cell characterizations were performed under ambient conditions unless otherwise specified. Results The ionic conductivity of the polymer electrolytes with different TEAOH:PAM ratios were measured and demonstrated remarkable ionic conductivities up to ca. 20 mScm-1 in the pristine condition. The trend revealed an optimal composition with 75-25 weight ratio of TEAOH-PAM. As shown in Figure 1, the TEAOH-PAM cells were tracked over a period of 50 days under ambient conditions and demonstrated good environmental stability. Further conditioning the cells under 45% RH showed an appropriate representation of the cells under steady-state. Details regarding ionic conductivity and long term stability will be discussed and related to the structural and chemical characterizations of these TEAOH-PAM polymer electrolytes. Finally, solid EC device performances will be compared to liquid TEAOH devices. References [1] K.-W. Nam and K.-B. Kim, "A study of the preparation of NiO x electrode via electrochemical route for supercapacitor applications and their charge storage mechanism," Journal of the Electrochemical Society, vol. 149, pp. A346-A354, 2002. [2] http://www.elton-cap.com/products/ [3] Y.-G. Wang, Z.-D. Wang, and Y.-Y. Xia, "An asymmetric supercapacitor using RuO 2/TiO 2 nanotube composite and activated carbon electrodes," Electrochimica Acta, vol. 50, pp. 5641-5646, 2005. [4] H. Gao, J. Li, K. Lian., "Alkaline quaternary ammonium hydroxides and their polymer electrolytes for electrochemical capacitors," RCS Advances, vol. 4, pp. 21332-21339, 2014. [5] H. Gao, J. Li, J. R. Miller, R. A. Outlaw, S. Butler, and K. Lian, "Solid-state electric double layer capacitors for ac line-filtering," Energy Storage Materials, vol. 4, pp. 66-70, 2016. Figure 1
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».