115 Clinical Decision Making in the Care of Preterm Infants at Risk of BPD Varies Significantly between Canadian Neonatologists
Notice bibliographique
Résumé
The Canadian Neonatal Network is studying the effects of collaborative quality improvement on NICU outcomes, including Bronchopulmonary Dysplasia (BPD). To describe common decision-making criteria in respiratory care of newborns, variation between practitioners, and correlation of practice with scientific evidence. We developed a 53-item questionnaire that examined clinical practice re: respiratory support, monitoring, weaning protocols, discharge criteria, use of diagnostic tests, fluids and medications, and personnel. Most questions were multiple choice. The questionnaire was distributed to all staff neonatologists in the study network in summer 2003. 28 neonatologists completed surveys. Management varied considerably among respondents. Forty-five percent would administer surfactant immediately after intubation to an infant <28 weeks gestation with RDS, while 48% would require x-ray confirmation. Thirty-four percent used high frequency ventilation routinely. The modal combination of monitoring was arterial line plus oxygen saturation monitor. Fifty percent used computerized respiratory waveforms to guide decision-making. Between rounds, decisions about respiratory care were made by Fellows (16), Residents (14), Respiratory Therapists (10) Nurse Practitioners (11), Clinical Assistants (9) Nurses (1) or Neonatologists (1). Fifty percent of clinicians reported using weaning protocols for RDS, usually administered by RTs. For preterm infants with RDS, the range of preferred maximum PaO2 was 60–90 torr; preferred maximum PaCO2, 45 torr to no limit; preferred minimum PaCO2, 30–45 torr. The modal range of preferred oxygen saturation was 88–92% (range 85–95%). For infants developing BPD, modal maximum and minimum PaCO2 was 60 and 40 torr, respectively. There was no consistent preferred range of oxygen saturation for BPD (range 85–98%). Many modes of ventilation were preferred; 13 of 28 respondents used volume guarantee during the weaning phase. FiO2 was used as a criterion of extubation readiness in 23/28 cases, but clinical criteria were inconsistent. Forty-eight percent used methylxanthines as an aid to extubation. The maximum CPAP used ranged from 5 to >10 cm H2O. Use of nasal flow oxygen was very inconsistent. Seven percent of clinicians never discharged infants on oxygen; 4% did so routinely. Seventeen clinicians reported using postnatal steroids for the treatment of BPD; 11 administered them systemically. The timing, dose and consent policies were not consistent. Vitamins A or E were not routinely used. Canadian neonatologists' clinical decision making varies considerably even when scientific evidence is clear. Ongoing studies will address the influence of participation in benchmarking networks on the standardization of care and on clinical outcomes.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,007 | 0,037 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,002 |
| Études des sciences et des technologies | 0,003 | 0,001 |
| Communication savante | 0,002 | 0,000 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,005 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».