A Blackout caused by Multiple Lightning Strikes to a Lightly-loaded Interconnection Consisting of Three 500 kV Power Lines in a Joint Corridor
Notice bibliographique
Résumé
Blackouts usually occur when a heavily-loaded transmission interconnection is subjected to a disturbance that pushes it over the stability limit. In this case, a blackout was caused by multiple lightning strikes to a transmission link consisting of three parallel 500 kV power lines carrying a small fraction of their rated load. The incident caused the islanding of seven power stations, the shedding of 663 MW of generation, a regional blackout in British Columbia, Canada that affected 34,500 customers and damage to the equipment of a major customer. One of the subject lines experienced a double line-to-ground fault, and the other two lines experienced single line-to-ground faults. It took about 3.25 hours to end the blackout and totally restore the system to its pre-outage condition. The following unusual phenomena were encountered during this incident: a) 9 Hz ferroresonance currents that triggered the relay of the shunt reactor bank of the 500 kV line which experienced the double line-to-ground fault, and; b) Ferranti Effect overvoltages that reached 148% at the remote end of a chain of 138 kV & 230 kV lightly-loaded lines that became electrically connected in series, with no voltage control at the intermediate points. This paper gives a review of both this incident and a prior unreported one which also caused a regional blackout and presents the lessons learned from them.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».