MétaCan
Menu
Retour à la cohorte
Enregistrement W2947213077 · doi:10.1016/s1473-3099(19)30001-5

Novel lipoarabinomannan point-of-care tuberculosis test for people with HIV: a diagnostic accuracy study

2019· article· en· W2947213077 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

affAu moins un auteur déclare une institution canadienne dans l'instantané OpenAlex épinglé.

Notice bibliographique

RevueThe Lancet Infectious Diseases · 2019
Typearticle
Langueen
DomaineMedicine
ThématiqueTuberculosis Research and Epidemiology
Établissements canadiensAlberta Glycomics CentreUniversity of Alberta
Organismes subventionnairesNational Institute of Allergy and Infectious DiseasesMedical Research CouncilNational Institutes of HealthEuropean and Developing Countries Clinical Trials PartnershipGlobal Health Innovative Technology FundMinisterie van Buitenlandse ZakenUniversity of Cape TownBundesministerium für Bildung und ForschungCoordenação de Aperfeiçoamento de Pessoal de Nível SuperiorDepartment of Science and Technology, Ministry of Science and Technology, IndiaDepartment of Foreign Affairs and Trade, Australian GovernmentSouth African Medical Research CouncilNational Department of HealthNational Research FoundationNational Research Foundation of KoreaWellcome TrustDepartment for International Development, UK GovernmentBill and Melinda Gates Foundation
Mots-clésMedicineLipoarabinomannanTuberculosisInternal medicineUrineGold standard (test)Human immunodeficiency virus (HIV)Prospective cohort studyMycobacterium tuberculosisPoint-of-care testingTuberculosis diagnosisPoint of careImmunologyPathology

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Most tuberculosis-related deaths in people with HIV could be prevented with earlier diagnosis and treatment. The only commercially available tuberculosis point-of-care test (Alere Determine TB LAM Ag [AlereLAM]) has suboptimal sensitivity, which restricts its use in clinical practice. The novel Fujifilm SILVAMP TB LAM (FujiLAM) assay has been developed to improve the sensitivity of AlereLAM. We assessed the diagnostic accuracy of the FujiLAM assay for the detection of tuberculosis in hospital inpatients with HIV compared with the AlereLAM assay. METHODS: For this diagnostic accuracy study, we assessed biobanked urine samples obtained from the FIND Specimen Bank and the University of Cape Town Biobank, which had been collected from hospital inpatients (aged ≥18 years) with HIV during three independent prospective cohort studies done at two South African hospitals. Urine samples were tested using FujiLAM and AlereLAM assays. The conduct and reporting of each test was done blind to other test results. The primary objective was to assess the diagnostic accuracy of FujiLAM compared with AlereLAM, against microbiological and composite reference standards (including clinical diagnoses). FINDINGS: Between April 18, 2018, and May 3, 2018, urine samples from 968 hospital inpatients with HIV were evaluated. The prevalence of microbiologically-confirmed tuberculosis was 62% and the median CD4 count was 86 cells per μL. Using the microbiological reference standard, the estimated sensitivity of FujiLAM was 70·4% (95% CI 53·0 to 83·1) compared with 42·3% (31·7 to 51·8) for AlereLAM (difference 28·1%) and the estimated specificity of FujiLAM was 90·8% (86·0 to 94·4) and 95·0% (87·7-98·8) for AlereLAM (difference -4·2%). Against the composite reference standard, the specificity of both assays was higher (95·7% [92·0 to 98·0] for FujiLAM vs 98·2% [95·7 to 99·6] for AlereLAM; difference -2·5%), but the sensitivity of both assays was lower (64·9% [50·1 to 76·7] for FujiLAM vs 38·2% [28·1 to 47·3] for AlereLAM; difference 26·7%). INTERPRETATION: In comparison to AlereLAM, FujiLAM offers superior diagnostic sensitivity, while maintaining specificity, and could transform rapid point-of-care tuberculosis diagnosis for hospital inpatients with HIV. The applicability of FujiLAM for settings of intended use requires prospective assessment. FUNDING: Global Health Innovative Technology Fund, UK Department for International Development, Dutch Ministry of Foreign Affairs, Bill & Melinda Gates Foundation, German Federal Ministry of Education and Research, Australian Department of Foreign Affairs and Trade, Wellcome Trust, Department of Science and Technology and National Research Foundation of South Africa, and South African Medical Research Council.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,007
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,007
Score d'incertitude au seuil0,864

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,007
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,019
Tête enseignante GPT0,313
Écart entre enseignants0,294 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle