Design and synthesis of a novel fluorescent probe, Eu<sup>III</sup>-dtpa-bis(adenine), and application for the detection of orotic acid in urine
Notice bibliographique
Résumé
For detection of orotic acid (OA), a novel fluorescent probe, Eu III -dtpa-bis(adenine), was designed and synthesized based on the complementation base pairing principle. The dtpa-bis(adenine) ligand was characterized by nuclear magnetic resonance spectroscopy ( 1 H NMR and 13 C NMR), Fourier transform infrared spectra (FTIR), and elemental analysis. Then, the effects of solution pH values and some coexisting interfering substances on OA detection using Eu III -dtpa-bis(adenine) as a fluorescent probe were investigated. The linear relationship of F 0 /F and OA concentration in the range of 10–150 μmol/L was obtained, where F 0 and F are the fluorescence intensities of Eu III -dtpa-bis(adenine) at 320 nm in the absence and presence of OA, respectively. The calculated limit of detection is about 0.807 μmol/L. The detection mechanism of OA was proposed. In addition, the detection of OA in urine samples has also been studied. It was found that the designed and synthesized fluorescent probe is effective for the detection of OA in urine samples.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».