MétaCan
Menu
Retour à la cohorte
Enregistrement W2969310179 · doi:10.1001/jamaneurol.2019.2478

Evaluation of the Central Vein Sign as a Diagnostic Imaging Biomarker in Multiple Sclerosis

2019· article· en· W2969310179 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

affAu moins un auteur déclare une institution canadienne dans l'instantané OpenAlex épinglé.
fundUn bailleur canadien est enregistré sur le travail.

Notice bibliographique

RevueJAMA Neurology · 2019
Typearticle
Langueen
DomaineMedicine
ThématiqueMultiple Sclerosis Research Studies
Établissements canadiensUniversity of TorontoSt. Michael's Hospital
Organismes subventionnairesSanofi GenzymeChugai PharmaceuticalAmsterdam NeuroscienceFundació Institut de Recerca Hospital Universitari Vall d’HebronMedizinische Universität GrazBerlin Institute of HealthBundesministerium für Bildung und ForschungUniversità degli Studi di VeronaAlexion PharmaceuticalsUniversity of TorontoVrije Universiteit AmsterdamSanofiHumboldt-Universität zu BerlinBayer HealthCareEuropean CommissionAmsterdam University Medical CentersBiogenCelgeneUniwersytet Medyczny im. Karola Marcinkowskiego w PoznaniuFreie Universität BerlinKarl-Franzens-Universität GrazEli Lilly and CompanyUniwersytet Mikolaja Kopernika w ToruniuArthur Arnstein StiftungTeva Pharmaceutical IndustriesUniversità degli Studi di Siena
Mots-clésMedicineMultiple sclerosisNeuroimagingMagnetic resonance imagingImaging biomarkerRadiologyBiomarkerObservational studyInternal medicinePsychiatry

Résumé

récupéré en direct d'OpenAlex

Importance: The central vein sign has been proposed as a specific imaging biomarker for distinguishing between multiple sclerosis (MS) and not MS, mainly based on findings from ultrahigh-field magnetic resonance imaging (MRI) studies. The diagnostic value of the central vein sign in a multicenter setting with a variety of clinical 3 tesla (T) MRI protocols, however, remains unknown. Objective: To evaluate the sensitivity and specificity of various central vein sign lesion criteria for differentiating MS from non-MS conditions using 3T brain MRI with various commonly used pulse sequences. Design, Setting, and Participants: This large multicenter, cross-sectional study enrolled participants (n = 648) of ongoing observational studies and patients included in neuroimaging research databases of 8 neuroimaging centers in Europe. Patient enrollment and MRI data collection were performed between January 1, 2010, and November 30, 2016. Data analysis was conducted between January 1, 2016, and April 30, 2018. Investigators were blinded to participant diagnosis by a novel blinding procedure. Main Outcomes and Measures: Occurrence of central vein sign was detected on 3T T2*-weighted or susceptibility-weighted imaging. Sensitivity and specificity were assessed for these MRI sequences and for different central vein sign lesion criteria, which were defined by the proportion of lesions with central vein sign or by absolute numbers of lesions with central vein sign. Results: A total of 606 participants were included in the study after exclusion of 42 participants. Among the 606 participants, 413 (68.2%) were women. Patients with clinically isolated syndrome and relapsing-remitting MS (RRMS) included 235 women (66.6%) and had a median (range) age of 37 (14.7-61.4) years, a median (range) disease duration of 2 (0-33) years, and a median (range) Expanded Disability Status Scale score of 1.5 (0-6.5). Patients without MS included 178 women (70.4%) and had a median (range) age of 54 (18-83) years. A total of 4447 lesions were analyzed in a total of 487 patients: 690 lesions in 98 participants with clinically isolated syndrome, 2815 lesions in 225 participants with RRMS, 54 lesions in 13 participants with neuromyelitis optica spectrum disorder, 54 lesions in 14 participants with systemic lupus erythematosus, 121 lesions in 29 participants with migraine or cluster headache, 240 lesions in 20 participants with diabetes, and 473 lesions in 88 participants with other types of small-vessel disease. The sensitivity was 68.1% and specificity was 82.9% for distinguishing MS from not MS using a 35% central vein sign proportion threshold. The 3 central vein sign lesion criteria had a sensitivity of 61.9% and specificity of 89.0%. Sensitivity was higher when an optimized T2*-weighted sequence was used. Conclusions and Relevance: In this study, use of the central vein sign at 3T MRI yielded a high specificity and a moderate sensitivity in differentiating MS from not MS; international, multicenter studies may be needed to ascertain whether the central vein sign-based criteria can accurately detect MS.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,016
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMétarecherche
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,116
Score d'incertitude au seuil0,993

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,016
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,084
Tête enseignante GPT0,318
Écart entre enseignants0,235 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle