MétaCan
Menu
Retour à la cohorte
Enregistrement W2995163852 · doi:10.1055/a-1066-4561

Pocket-creation method using a new technique of single-clip traction for colorectal endoscopic submucosal dissection

2019· article· en· W2995163852 sur OpenAlexaff
Tatsuma Nomura, Yoshikazu Hayashi, Ralph Lee, Takahito Takezawa, Keijiro Sunada, Hironori Yamamoto

Notice bibliographique

RevueEndoscopy · 2019
Typearticle
Langueen
DomaineMedicine
ThématiqueGastric Cancer Management and Outcomes
Établissements canadiensUniversity of Ottawa
Organismes subventionnairesnon disponible
Mots-clésEndoscopic submucosal dissectionMedicineTraction (geology)Dissection (medical)SurgeryRadiology

Résumé

récupéré en direct d'OpenAlex

Colorectal endoscopic submucosal dissection (ESD) is a challenging procedure used in the removal of colorectal neoplasms and various methods have been developed to improve its performance [ 1 ] [ 2 ] [ 3 ]. Among these, the pocket-creation method (PCM) allows the safe and efficient removal of neoplastic lesions, using precise submucosal dissection just above the muscularis propria [ 4 ] [ 5 ]. However, the pocket-opening phase of PCM is often cumbersome and time-consuming. We have invented a new technique using single-clip traction that we have called PCM with clip traction (PCM-CT), which we believe improves the speed and safety of the pocket-opening phase. PCM-CT creates submucosal traction by using a single hemoclip to affix normal mucosa from the distal side of the lesion to normal mucosa on the opposite colonic wall ([ Fig. 1 ]). This elongates the submucosa, enabling clearer identification of the safest submucosal dissection line. Fig. 1 Illustration of the pocket-creation method with clip traction (PCM-CT). a – c The submucosa below the lesion is dissected using the PCM; d a circumferential mucosal incision is created around the lesion; e, f a reopenable hemoclip is used to grasp normal mucosa on the distal edge of the partially resected lesion, without deployment; g the entrapped mucosa is pulled towards the normal mucosa on the opposite intestinal wall; h the hemoclip is slowly reopened to capture the opposing normal mucosa and the clip is deployed; i the remaining submucosa below the lesion is dissected with reliable identification of the safest submucosal dissection line. A 20-mm, Paris IIa, nongranular, JNET 2B, laterally spreading lesion in the proximal ascending colon (diagnosed on pathology as being a well differentiated slightly invasive submucosal adenocarcinoma with a 400-µm invasion depth, negative lymphovascular invasion, and negative margins) was removed using the PCM-CT ([ Fig. 2 ]; [ Video 1 ]). As per the standard PCM, a submucosal pocket was first created below the lesion. Next, a circumferential mucosal incision was performed approximately 7 mm outside the margin of the lesion. A reopenable hemoclip (SureClip; Micro-Tech Co. Ltd., NanJing, China) was used to grasp normal mucosa on the distal edge of the partially resected lesion, without being deployed. The resulting entrapped mucosa was then pulled towards the opposite colonic wall, where the hemoclip was carefully reopened to capture the opposing normal colonic mucosa. Once it was confirmed that both mucosal sites had been secured, the hemoclip was deployed. The remaining submucosa beneath the lesion was then dissected and the lesion was safely removed. Fig. 2 Endoscopic images showing: a a 20-mm, Paris IIa, nongranular, JNET 2B, laterally spreading lesion in the ascending colon; b colonic endoscopic submucosal dissection (ESD) being performed using the pocket-creation method (PCM); c a circumferential incision being made in the normal mucosa around the lesion after the submucosal pocket has been created; d normal mucosa on the distal edge of the lesion being captured with a reopenable clip; e the clip, with the captured mucosa from the edge of the lesion, being pulled towards the opposite colonic wall and reopened to entrap the opposing normal colonic mucosa as well; f the identification of the safest submucosal dissection line, which is improved after PCM with clip traction. Video 1 The pocket-creation method with clip traction (PCM-CT) is performed on a 20-mm laterally spreading lesion in the proximal ascending colon. Quality: mobile 360 480 720 Download In conclusion, PCM-CT provides continuous submucosal traction on lesions by stretching the submucosa and allowing clearer identification of the safest submucosal resection path. This technique facilitates the pocket-opening stage of PCM and potentially improves its safety and efficiency. Endoscopy_UCTN_Code_TTT_1AQ_2AD Endoscopy E-Videos https://eref.thieme.de/e-videos Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. This section has its own submission website at https://mc.manuscriptcentral.com/e-videos

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,002
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,005
Score d'incertitude au seuil0,016

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0010,002
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0010,002
Bibliométrie0,0010,001
Études des sciences et des technologies0,0010,001
Communication savante0,0010,002
Science ouverte0,0010,001
Intégrité de la recherche0,0010,002
Charge utile insuffisante (le modèle a refusé de juger)0,0050,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,031
Tête enseignante GPT0,347
Écart entre enseignants0,316 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations12
Publié2019
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueEndoscopyMême sujetGastric Cancer Management and OutcomesTravaux en français237 207