Preparation of mesoporous MCM‐41 supported zinc sorbents by microwave in‐situ oxidation for H<sub>2</sub>S removal in coal gas
Notice bibliographique
Résumé
Abstract Zn‐based MCM‐41 supporter sorbents were prepared using the microwave in‐situ oxidation method. Other sorbents were heated using a conventional heating method to contrast the performance for H 2 S removal. The sorbents were tested at 500°C in fixed reactor and dried simulated Texaco coal gas was employed for the sulphurized atmosphere. The results show that sorbents prepared by microwave oxidation had a better toleration for the adsorption of H 2 S. A 13.2% improvement occurred in the sulphur capacity of the sorbents heated by the microwave method. XRD, SEM with EDS‐element mapping, TEM, N 2 adsorption, and XPS were used to characterize the properties of the sorbents. Due to the selective heating of the microwave and the superiority of the in‐situ oxidation method, the sorbents heated by microwave exhibited more appropriate structures for sulphurization. Meanwhile, the even heating environment supplied by the microwave resulted in a more uniform distribution of the active component. The microwave also had an effect on the chemical bond and reduced the binding energy of the active component, which enhanced the reactivity between the H 2 S and the sorbents. The preferable features generated by microwave in‐situ oxidation accelerate the replacement of S to O, and therefore the Zn‐based MCM‐41 sorbents prepared by the microwave method have an increased capability for H 2 S removal in high temperature coal gas.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».