Stability of Reconstituted Fibrinogen Concentrate in Hemostatic Function and Concentration
Notice bibliographique
Résumé
INTRODUCTION: Canadian Armed Forces adopted fibrinogen concentrate (RiaSTAP) for hemostatic resuscitation in the far-forward combat setting, given its potential benefits of reducing blood loss, blood transfusion and mortality, and its long storage stability and high portability. The current guidance recommends that RiaSTAP should be administered within 8 hours after reconstitution when stored at room temperature. However, little information about its stability is available. There is also a need to investigate the stability and efficacy of RiaSTAP after reconstitution and exposure to extreme temperatures in which our forces may operate. MATERIALS AND METHODS: RiaSTAP was reconstituted as per manufacturer's instruction and stored at specific temperatures (-20°C, 4°C, 22°C, 35°C, 42°C, or 50°C) for up to 6 months. Reconstituted RiaSTAP was also oscillated on a rocker at 18 rpm under 22°C and 50°C. Its hemostatic function was measured using rotational thromboelastometry performed with RiaSTAP-spiked whole blood. Fibrinogen concentrations were measured by a commercial enzyme-linked immunosorbent assay (ELISA) kit. Gel electrophoresis was also conducted for initial and stored samples. RESULTS: We found no change to the hemostatic function of reconstituted RiaSTAP after storage at -20°C for 6 months. At 4°C, no obvious changes to the hemostatic effect of reconstituted RiaSTAP relative to 0 hours were seen until 1,680 hours. At 22°C, a remarkable decrease began after storage for 168 hours. Storage at 35°C significantly decreased the hemostatic effect after 144 hours, while the storage at 42°C resulted in decreased hemostatic function after 72 hours. Finally, storage at 50°C for 8 hours resulted in complete loss of hemostatic function. Compared to the hemostatic activity, the fibrinogen concentration for reconstituted RiaSTAP showed less change over time. No apparent decline in fibrinogen concentration was seen after storage at -20°C for 6 months and at 4°C for 1,680 hours. At 22°C, there were no clear alterations until 792 hours. There was a decline in fibrinogen concentration at 35°C and 42°C after 672 and 600 hours of storage, respectively. At 50°C, little amount of fibrinogen was detected by ELISA at 8 hours. Similar changes in the hemostatic effect and fibrinogen concentration over time were observed under the rocking condition in comparison with the static condition at the same temperature. The gel electrophoresis confirmed fibrinogen degradation which increased with storage temperature and time. CONCLUSIONS: The stability of reconstituted RiaSTAP decreases with increasing storage temperature. The hemostatic function deteriorated before fibrinogen concentration and integrity were significantly altered at all temperatures for the study period except at 50°C where there was a rapid decline in both hemostatic function and fibrinogen concentration. Sample oscillation did not significantly affect its stability. The shelf life of reconstituted RiaSTAP may, therefore, be recommended accordingly when stored at different temperatures and extended to 6 days at room temperature provided that sterility is maintained.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».