Changes to Biceps and Supraspinatus Tendons in Response to a Progressive Maximal Treadmill-Based Propulsion Aerobic Fitness Test in Manual Wheelchair Users: A Quantitative Musculoskeletal Ultrasound Study
Notice bibliographique
Résumé
Relevance. To develop personalized cardiorespiratory fitness training programs among manual wheelchair users and assess their impact over time, the completion of a performance-based maximal cardiorespiratory fitness test is required. However, these tests could potentially increase the risk exposure for the development of upper limb secondary musculoskeletal impairments. Hence, finding an equilibrium between the need to measure aerobic fitness and the increased risk of developing secondary musculoskeletal impairments when completing performance-based test is fundamental. Objective. To investigate if the completion of a recently developed treadmill-based wheelchair propulsion maximal progressive workload incremental test alters the integrity of the long head of the biceps and supraspinatus tendons using musculoskeletal ultrasound imaging biomarkers. Method. Fifteen manual wheelchair users completed the incremental test. Ultrasound images of the long head of the biceps and supraspinatus tendons were recorded before, immediately after, and 48 hours after the completion of the test using a standardized protocol. Geometric, composition, and texture-related ultrasound biomarkers characterized tendon integrity. Results. Participants propelled during <a:math xmlns:a="http://www.w3.org/1998/Math/MathML" id="M1"> <a:mn>10.2</a:mn> <a:mo>±</a:mo> <a:mn>2.9</a:mn> <a:mtext> </a:mtext> <a:mtext>minutes</a:mtext> </a:math> with the majority ( <c:math xmlns:c="http://www.w3.org/1998/Math/MathML" id="M2"> <c:mi>N</c:mi> <c:mo>=</c:mo> <c:mn>13</c:mn> <c:mo>/</c:mo> <c:mn>15</c:mn> </c:math> ) having reached at least the eighth stage of the <e:math xmlns:e="http://www.w3.org/1998/Math/MathML" id="M3"> <e:mtext>test</e:mtext> <e:mtext> </e:mtext> <e:mo stretchy="true">(</e:mo> <e:mtext>speed</e:mtext> <e:mo>=</e:mo> <e:mn>0.8</e:mn> <e:mtext> </e:mtext> <e:mtext>m</e:mtext> <e:mo>/</e:mo> <e:mtext>s</e:mtext> </e:math> ; <h:math xmlns:h="http://www.w3.org/1998/Math/MathML" id="M4"> <h:mtext>slope</h:mtext> <h:mo>=</h:mo> <h:msup> <h:mrow> <h:mn>3.6</h:mn> </h:mrow> <h:mrow> <h:mo>°</h:mo> </h:mrow> </h:msup> </h:math> ). All ultrasound biomarkers characterizing tendon integrity, measured in the longitudinal and transversal planes for both tendons, were similar ( <j:math xmlns:j="http://www.w3.org/1998/Math/MathML" id="M5"> <j:mi>p</j:mi> <j:mo>=</j:mo> <j:mn>0.063</j:mn> </j:math> to 1.000) across measurement times. Conclusion. The performance of the motorized treadmill wheelchair propulsion test to assess aerobic fitness produced no changes to ultrasound biomarkers of the biceps or supraspinatus tendons. Hence, there was no ultrasound imaging evidence of a maladaptive response due to overstimulation in these tendons immediately after and 48 hours after the performance of the test.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,008 | 0,179 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,002 | 0,004 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».