Validity and Interinstrument Reliability of a Medical Grade Physical Activity Monitor in Older Adults

2021· article· en· 4 citations· W3134685310 sur OpenAlex· 10.1123/jmpb.2019-0074

Pourquoi ce travail est-il dans la base ?

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

Affiliation canadienneUne personne signataire a déclaré un établissement canadien. C'est la seule voie dont dispose la base habituelle.

Le tri à trois modèles

les 1 000 travaux triés →

Les trois modèles l'ont jugé hors champ.

strate : aff_core · poids de sondage : 5595.24 (l'échantillon est stratifié ; tout taux calculé sans le poids est faux)
Claude Opus 4.8OUT
genre : empirical
porte sur le Canada: non
confiance: high

Validity and reliability study of a physical activity monitor device in older adults; instrument validation for a clinical measure, not research methodology.

GPT-5.6 (high)OUT
genre : empirical
porte sur le Canada: non
confiance: high

It validates a physical-activity monitor for health measurement rather than studying research methods.

Grok 4.5OUT
genre : empirical
porte sur le Canada: non
confiance: high

Instrument validity/reliability of a fitness monitor is assay-style measurement validation, not study of research methods.

Résumé

Wearable physical activity monitors are associated with an increase in user’s habitual physical activity levels. Most of the older adult population do not meet the national moderate- to vigorous-intensity physical activity (MVPA) recommendations and may benefit from being prescribed a physical activity monitor. The PiezoRx is a class one medical grade device that uses step rate thresholds to measure MVPA. The validity and reliability of the PiezoRx in measuring MVPA has yet to be determined in older persons. We assessed the validity and interinstrument reliability of the PiezoRx to measure steps and MVPA in older adults. Participants ( n = 19; 68.8 ± 2.3 years) wore an Omron HJ-320 pedometer, ActiGraph GT3X accelerometer, and four PiezoRx monitors during a five-stage treadmill walking protocol. The PiezoRx devices were set at moderate physical activity and vigorous physical activity step rate thresholds (steps per minute) of 100/120, 110/130, adjusted for height and adjusted for height + fitness. The PiezoRx exhibited a stronger correlation (intraclass correlation coefficient = .82) with manually counted steps than the ActiGraph (intraclass correlation coefficient = .53) and Omron (intraclass correlation coefficient = .54) and had a low absolute percentage error (3 ± 6%). The PiezoRx with moderate physical activity/vigorous physical activity step thresholds adjusted to 110/130 was strongly correlated to indirect calorimetry (0.84, p < .001) and best distinguished each walking stage as MVPA or not (sensitivity: 88%; specificity: 95%). The PiezoRx monitor is a valid and reliable measure of step count and MVPA among older adults. The device’s ability to measure MVPA in absolute terms was improved when step rate thresholds for moderate physical activity/vigorous physical activity were increased to 110/130 steps per minute in this population.

Conservé avec la notice de tri, où il sert de preuve aux étiquettes ci-dessus.

La notice

Revue
Journal for the Measurement of Physical Behaviour
Thématique
Physical Activity and Health
Domaine
Medicine
Établissements canadiens
Acadia UniversityDalhousie University
Organismes subventionnaires
Mots-clés
Intraclass correlationPedometerPhysical activityPhysical therapyTreadmillReliability (semiconductor)MedicineCriterion validityPopulationValidityPhysical fitnessPhysical medicine and rehabilitationConstruct validityPsychometrics
Résumé présent dans OpenAlex
oui