Using shell-type tuyeres at Pierce–Smith horizontal converters of the Nadezhda Metallurgical Plant
Notice bibliographique
Résumé
Since 2015 the processing capacity reconfiguration at the Polar Branch of MMC Norilsk Nickel (hereinafter PB) sets new goals for conventional pyrometallurgical processes of smelting and converting. The design flowsheet of Kolesnikov Nadezhda Metallurgical Abstract: Plant (hereinafter NMP) provided for «cross-converting» when copper matte was first processed in one converter to produce blister copper followed by nickel matte processing to yield copper-nickel converter matte bypassing the discharge of dry coagulated slag. This flowsheet allowed for converter heat balance optimization, decreasing the formation of refractory reverts and significant extension of the converter campaign. PB Nickel Plant shutdown resulted in copper processing elimination at NMP and switching the converters to the conventional nickel converting flowsheet. In turn, it gave rise to the need for solutions to extend converter campaign while maintaining the possibility to process large amounts of nickel slag from the second converting stage at the PB Copper Plant. For this purpose the series of lab experiments were carried out to develop the technology and design documentation for the system to supply oxygen-enriched air (up to 45 %) to horizontal converters using shell-type tuyeres. In addition, literature data were analyzed on this topic along with the experience of smelters in this area. Process design calculations were done. The efforts were taken in cooperation with the PB engineering personnel and Laboratory of Pyrometallurgy of LLC «Gipronickel Institute». The use of reduced diameter shell-type tuyeres to inject the oxygen-air mixture was found to decrease the converter blowing and off-gas volumes. The decline in off-gas quantity leads to reduced heat load on the converter mouth and flue duct system, as well as to lowered converter dust entrainment. The use of oxygen-enriched blowing implies the higher smelt heating rate. Excess heat compensation requires timely charging of cold reverts and flux. In emergencies (if cold reverts are not available) the oxygen content of the blowing has to be reduced until switching over to air blowing. The series of the above efforts will offer a possibility to use the shell-type tuyeres keeping the converter off-gas temperature at the current level. Thus continuous monitoring and efficient control will ensure the off-gas temperature and volume at the inlets of gas cooling and cleaning systems not exceeding the limiting values. The introduction of the reduced diameter shell-type tuyeres for air-oxygen mixture injection does not require any upgrade of the existing gas cooling and cleaning systems. Moreover, switching to these tuyeres will reduce gas load on the flue duct system and heat load on the water-cooled dust cap, lower dust entrainment and non-recoverable dust losses after the gas cleaning system.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».