Using shell-type tuyeres at Pierce–Smith horizontal converters of the Nadezhda Metallurgical Plant
Bibliographic record
Abstract
Since 2015 the processing capacity reconfiguration at the Polar Branch of MMC Norilsk Nickel (hereinafter PB) sets new goals for conventional pyrometallurgical processes of smelting and converting. The design flowsheet of Kolesnikov Nadezhda Metallurgical Abstract: Plant (hereinafter NMP) provided for «cross-converting» when copper matte was first processed in one converter to produce blister copper followed by nickel matte processing to yield copper-nickel converter matte bypassing the discharge of dry coagulated slag. This flowsheet allowed for converter heat balance optimization, decreasing the formation of refractory reverts and significant extension of the converter campaign. PB Nickel Plant shutdown resulted in copper processing elimination at NMP and switching the converters to the conventional nickel converting flowsheet. In turn, it gave rise to the need for solutions to extend converter campaign while maintaining the possibility to process large amounts of nickel slag from the second converting stage at the PB Copper Plant. For this purpose the series of lab experiments were carried out to develop the technology and design documentation for the system to supply oxygen-enriched air (up to 45 %) to horizontal converters using shell-type tuyeres. In addition, literature data were analyzed on this topic along with the experience of smelters in this area. Process design calculations were done. The efforts were taken in cooperation with the PB engineering personnel and Laboratory of Pyrometallurgy of LLC «Gipronickel Institute». The use of reduced diameter shell-type tuyeres to inject the oxygen-air mixture was found to decrease the converter blowing and off-gas volumes. The decline in off-gas quantity leads to reduced heat load on the converter mouth and flue duct system, as well as to lowered converter dust entrainment. The use of oxygen-enriched blowing implies the higher smelt heating rate. Excess heat compensation requires timely charging of cold reverts and flux. In emergencies (if cold reverts are not available) the oxygen content of the blowing has to be reduced until switching over to air blowing. The series of the above efforts will offer a possibility to use the shell-type tuyeres keeping the converter off-gas temperature at the current level. Thus continuous monitoring and efficient control will ensure the off-gas temperature and volume at the inlets of gas cooling and cleaning systems not exceeding the limiting values. The introduction of the reduced diameter shell-type tuyeres for air-oxygen mixture injection does not require any upgrade of the existing gas cooling and cleaning systems. Moreover, switching to these tuyeres will reduce gas load on the flue duct system and heat load on the water-cooled dust cap, lower dust entrainment and non-recoverable dust losses after the gas cleaning system.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".